This study utilized a facile one-pot protocol to synthesize Ni-cobalt zeolitic imidazolate framework (Ni-ZIF-67) nanocomposite, which was then characterized by Fourier transform infrared spectroscopy, X-ray diffraction, energy dispersive X-ray spectroscopy and scanning electron microscopy. The Ni-ZIF-67 nanocomposite was subsequently applied to modify a screen-printed electrode (SPE) as a durable sensor for detection of Sudan I concomitantly with bisphenol A (BPA), with remarkably increased electrochemical response when comparing with a bare SPE. The results showed the calibration plot to be linear in the concentration range between 0.03 μM and 535.0 μM, with a narrow limit of detection of 9.0 nM (S/N = 3). Our proposed protocol was successful in detecting target analytes in real tap water and food specimens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fct.2022.112824DOI Listing

Publication Analysis

Top Keywords

ni-zif-67 nanocomposite
12
screen-printed electrode
8
amplified electrochemical
4
electrochemical sensor
4
sensor employing
4
employing screen-printed
4
electrode modified
4
modified ni-zif-67
4
nanocomposite high
4
high sensitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!