A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of Gamma and Ethylene Oxide Sterilization on a Selection of Active Pharmaceutical Ingredients for Ophthalmics. | LitMetric

Ensuring the sterility of life science products plays a pivotal role in the healthcare sector. Gamma irradiation and ethylene oxide sterilization are two commonly applied methods for the sterilization of medical devices, packaging components and Active Pharmaceutical Ingredients (API) for medicinal products. Focussed studies on the effects of sterilization processes on APIs remain limited. In this research study, five APIs, frequently used in sterile ophthalmic preparations were subjected to both gamma irradiation and ethylene oxide under different process conditions. The following APIs of GMP quality were selected: dexamethasone, aciclovir, tetracycline hydrochloride, triamcinolone and methylprednisolone. Analyses were performed using High Performance Liquid Chromatography equipped with UV detection and the effect of sterilization conditions on the APIs was evaluated by the assay and related substances test prescribed by the European Pharmacopoeia (Ph. Eur.). It was concluded that exposure to ethylene oxide resulted in compliance with Ph. Eur. for all APIs. While dexamethasone and methylprednisolone did not meet the requirement for the Ph. Eur. after exposure to gamma irradiation, the other three APIs did meet the requirement under the specified irradiation conditions. Subsequent optimization of sterilization parameters positively influenced the compliance to the Ph. Eur. requirements.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.xphs.2022.01.020DOI Listing

Publication Analysis

Top Keywords

ethylene oxide
16
gamma irradiation
12
oxide sterilization
8
active pharmaceutical
8
pharmaceutical ingredients
8
irradiation ethylene
8
conditions apis
8
compliance eur
8
meet requirement
8
sterilization
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!