A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of photostimulable phosphor image plate artifacts and their prevalence. | LitMetric

AI Article Synopsis

  • Digital radiography is becoming popular in dentistry, offering advantages over traditional film methods, including better recording and analysis of radiographic data.
  • The study aimed to identify the frequency and reasons for image artifacts in intraoral radiographs obtained using photostimulable phosphor plates (PSP).
  • Out of 50,000 radiographs evaluated over two years, 7.1% required retakes due to artifacts, with the most common issues being operator errors (especially cone cuts), plate errors (like bite marks), and scanning errors (primarily delayed scans).

Article Abstract

Background: Digital radiography has recently been used in dentistry as a substitute for conventional film radiography worldwide. Digital imaging has many advantages and provides new possibilities for recording and interpreting radiographic data. This system uses different types of digital receptors.

Aim: To detect the frequency, type, and reasons behind the appearance of intraoral image artifacts acquired by photostimulable phosphor plates (PSP).

Methods: This retrospective descriptive study was conducted in the oral and maxillofacial radiology unit of the dental clinics of the College of Dentistry, Princess Nourah University (PNU). All intraoral digital radiographs were acquired using (Gendex Expert DC., United States) an intraoral X-ray machine with 7 -mA, 65-kVP using a PSP system (Soredex DIGORA Optime imaging plate) and laser scanners (Soredex DIGORA Optime), which can house all sizes of reusable intraoral PSP sensor plates with image acquisition software (MIPACS Dental Enterprise viewer 3.2.2). A total of 50000 intraoral radiographs were retrieved from the clinical database from April 2018 to April 2020 to evaluate the reason, type, and solutions to these image artifacts.

Results: Overall, 50000 intraoral digital radiographs were acquired in a two-year-period; that is, from April 2018 to April 2020. Of these, 3550 (7.1%) retakes were performed due to the presence of image artifacts. Periapical radiographs were the most common image type of intraoral retakes (80.8%). Imaging artifacts were divided into three categories: operator, plate and scanning errors. Out of 3550 retakes, 5%, 1.37%, and 0.73% were related to operator, plate, and scanning errors, respectively. The cone cut was the most common operator error (988 images), Bite marks were the most common plate error (276 images), and delayed scanning artifacts were the most common scanning errors (145 images). The calculated kappa value for interobserver reliability was 0.99, indicating almost perfect interobserver agreement.

Conclusion: Our study discussed intraoral image artifacts that were characteristic of PSP, where the most common artifacts were bitemarks, image size reduction, scratches, and delayed scanning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8771371PMC
http://dx.doi.org/10.12998/wjcc.v10.i2.437DOI Listing

Publication Analysis

Top Keywords

image artifacts
12
scanning errors
12
photostimulable phosphor
8
image
8
intraoral
8
intraoral image
8
intraoral digital
8
digital radiographs
8
radiographs acquired
8
soredex digora
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!