A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Plug-and-play advanced magnetic resonance spectroscopy. | LitMetric

Plug-and-play advanced magnetic resonance spectroscopy.

Magn Reson Med

Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.

Published: June 2022

Purpose: Advanced MRS protocols improve data quality and reproducibility relative to vendor-provided protocols; however, they are challenging to incorporate into the clinical workflow and require local MRS expertise for successful implementation. Here, we developed an automated advanced MRS acquisition protocol at 3T to facilitate acquisition of high-quality spectroscopic data without local MRS expertise.

Methods: First, a B shimming protocol was selected for automation by comparing 3 widely used B algorithms (2 vendor protocols and FAST(EST)MAP). Next, voxel-based B and B calibrations were incorporated into the consensus-recommended semi-LASER sequence and combined with an automated VOI prescription tool, a recently developed method for automated voxel prescription. The efficiency of collecting single-voxel data from a clinical cohort (N = 40) with the automated protocol (calibration time and fraction of usable datasets) was compared with the nonautomated semi-LASER protocol (N = 35) whereby all prescan calibrations were executed manually in the academic hospital setting with rotating MR technologists in the neuroradiology unit.

Results: A multi-iteration FAST(EST)MAP protocol resulted in narrower water linewidths than vendor's B shim protocols for data acquired from 6 brain locations (p < 1e-5) and was selected for automation. The automated B and B calibrations resulted in a time saving of ~4.5 minutes per voxel relative to the same advanced protocol executed manually. All spectra acquired with the automated protocol were usable, whereas only 86% of those collected with the manual protocol were usable and spectral quality was more variable.

Conclusion: The plug-and-play advanced MRS protocol allows automated acquisition of high-quality MRS data with high success rate and consistency on a clinical 3T platform.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8957599PMC
http://dx.doi.org/10.1002/mrm.29164DOI Listing

Publication Analysis

Top Keywords

protocol
9
plug-and-play advanced
8
acquisition high-quality
8
selected automation
8
automated protocol
8
executed manually
8
advanced protocol
8
protocol usable
8
automated
7
data
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!