Effects of Adjacent Tooth Type and Occlusal Fatigue on Proximal Contact Force of Posterior Bulk Fill and Incremental Resin Composite Restoration.

Oper Dent

*Carlos José Soares, DDS, MSc, PhD, professor, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlandia, Minas Gerais, Brazil.

Published: January 2022

Objectives: To measure the proximal contact force in newtons (N) between incremental and bulk fill class II resin composite restorations and implant molar teeth or adjacent premolar teeth with simulated periodontal ligament.

Methods: The model used was created with a typodont first molar tooth with two bilateral occlusal-proximal class II cavities, an adjacent tooth simulating an implanted molar tooth (Titamax CM, Neodent, Curtiba, PR, Brazil) and a premolar with simulated periodontal ligament. Two resin composite restorative techniques were used: Inc-Z350XT, (Filtek Z350, 3M Oral Care, St. Paul, MN, USA) inserted incrementally and Bulk-OPUS, (Opus Bulk Fill APS, FGM, Joinville, SC, Brazil) high viscosity bulk fill resin composite (n=10). As a control, a typodont having intact teeth without restorations was used. After the restorative procedure, each specimen was radiographed using a digital system (Dürr Dental, Bietigheim-Bissingen, Germany). The proximal contact force (N) was measured using dental floss with a microtensile machine (Microtensile ODEME, Luzerna, SC, Brazil). The specimens were then subjected to mechanical fatigue cycling to simulate 5 years of aging. All the parameters were measured after aging. The X-rays were blindly qualitatively analyzed by two operators to identify the loss of proximal contact. One-way ANOVA was used for comparing the initial contact force between restored and intact teeth. Two-way ANOVA followed by Tukey testing was performed for contact area data and for the contact force/contact area ratio. The proximal contact force data were analyzed using one-way repeated measurement ANOVA followed by Tukey testing (α=0.05). The X-ray proximal contact analyses were described by the frequency.

Results: The initial proximal contact force was similar for intact and restored teeth. The contact force and contact area with the molar were significantly higher than with the premolar; however the contact force/contact area ratio was similar for all tested groups. The bulk fill technique showed a contact force similar to the incremental filling technique. Fatigue resulted in a significant reduction in the proximal contact force (p<0.001), irrespective of the region analyzed or restorative material used. The digital X-rays detected no alteration in the proximal contact after occlusal fatigue.

Conclusions: Larger contact area resulted in higher proximal contact force. Proximal contact force decreased with 5 years of simulated occlusal fatigue. The bulk fill technique showed a proximal contact force similar to that of the incremental filling technique.

Download full-text PDF

Source
http://dx.doi.org/10.2341/20-019-LDOI Listing

Publication Analysis

Top Keywords

contact force
36
proximal contact
32
bulk fill
20
resin composite
16
contact
15
force
9
adjacent tooth
8
proximal
8
simulated periodontal
8
molar tooth
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!