Objectives: This study was performed to determine the clinical and haemodynamic variables associated with early adverse outcomes after the neonatal Norwood procedure.

Methods: Patients who underwent the neonatal Norwood procedure between 2001 and 2019 were included. The patient diagnosis, morphological characteristics and haemodynamic parameters were analysed to identify factors associated with length of stay (LOS) in the intensive care unit (ICU) and mortality during the stay.

Results: A total of 322 patients were depicted. The median age and weight at the Norwood procedure were 9 days and 3.2 kg, respectively. Certain morphological and preoperative parameters, such as birth weight below 2.5 kg, restrictive atrial septal defect, extracardiac anomalies and the diameter of the ascending aorta, were found to be associated with the LOS in the ICU. Analysis using early postoperative haemodynamic variables revealed that systolic arterial pressure, diastolic arterial pressure, serum lactate levels and reduced ventricular function at 2 days postoperatively were associated with the LOS in the ICU. Birth weight <2.5 kg (P = 0.010), a restrictive atrial septal defect (P = 0.001) and smaller ascending aorta (P = 0.039) were associated with death in the ICU. Reduced ventricular function, lower systolic aortic pressure and higher lactate levels at various time points (P < 0.05) were also associated with ICU deaths. The LOS in the ICU was significantly associated with late mortality (P < 0.001, Hazard Ratio (HR) = 1.015).

Conclusions: The LOS in the ICU after the Norwood procedure was predicted by early postoperative haemodynamic variables, suggesting that good early postoperative haemodynamics determine early recovery. A prolonged stay in the ICU after the Norwood procedure was associated with late mortality.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezac014DOI Listing

Publication Analysis

Top Keywords

haemodynamic variables
12
norwood procedure
12
clinical haemodynamic
8
variables associated
8
intensive care
8
care unit
8
length stay
8
early adverse
8
adverse outcomes
8
neonatal norwood
8

Similar Publications

Background: Motor imagery is the mental representation of a movement without physical execution. When motor imagery is performed to enhance motor learning and performance, participants must reach a temporal congruence between the imagined and actual movement execution. Identifying factors that can influence this capacity could enhance the effectiveness of motor imagery programs.

View Article and Find Full Text PDF

Increased blood pressure upon standing is considered a cardiovascular risk factor. We investigated the reproducibility of changes in aortic blood pressure, heart rate, stroke volume, cardiac output, and systemic vascular resistance during three passive head-up tilts (HUT) in 223 participants without cardiovascular medications (mean age 46 years, BMI 28 kg/m2, 54% male). Median time gap between the first and the second HUT was 9 weeks and the second and the third HUT 4 weeks.

View Article and Find Full Text PDF

Background: Hemophagocytic lymphohistiocytosis (HLH) is an immunologic syndrome characterized by excessive inflammation and tissue injury due to uncontrolled activation of the phagocytic system. The underlying mechanism is a lack of downregulation of activated macrophages and lymphocytes by natural killer and T cells. Unfortunately, the diagnosis is often delayed or missed due to the rarity of the disease, decreased awareness, and clinical picture variability.

View Article and Find Full Text PDF

Background: The Society of Cardiovascular Angiography and Intervention (SCAI) has defined 5 stages of cardiogenic shock (CS). In patients with acute myocardial infarction (AMI) who initially present in stable hemodynamic condition (SCAI CS stage: A or B), CS stages could deteriorate despite therapeutic management. However, deterioration of SCAI CS stages after AMI remains to be fully characterized.

View Article and Find Full Text PDF

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!