Purpose: To radiographically compare lateral entry point S2-alar-iliac (L-S2AI) screw with conventional S2AI (C-S2AI) and conventional iliac screw (CIS) lengths and trajectories.
Methods: Twenty-five preoperative CT scans of consecutive patients undergoing adult spinal deformity realignment surgery over a random 2-year period were analysed. Maximum in-bone length, caudal and lateral trajectories of CIS, C-S2AI, and L-S2AI screws were measured and compared using One-way ANOVA with Tukey's post hoc tests. Multivariate logistic regression was performed to identify predictors of high screw length discrepancy between C-S2AI and L-S2AI.
Results: Potential screw length was longest for CIS, followed by L-S2AI, then C-S2AI (114.5 ± 8.3 mm vs 101.4 ± 9.6 mm vs 80.6 ± 5.9 mm, respectively) in all patients (p < 0.001). Actual screw lengths found both CIS and L-S2AI to be longer than C-S2AI (95.3 ± 8.5 mm and 93.4 ± 7.5 mm vs 82.1 ± 7.3 mm; p = 0.008 and 0.003). Potential lateral angulation was smallest for CIS, followed by L-S2AI, then C-S2AI (21.9 ± 7.0° vs 31.9 ± 7.1° vs 40.9 ± 6.7°, respectively) in all patients (p < 0.001). L-S2AI and C-S2AI had the same caudal angulation (24.9 ± 6.8°), which was smaller than CIS (30.8 ± 5.8°) in all patients (p < 0.001). Univariate, but not multivariate analysis, revealed that lumbar lordosis > 40° (OR 7.2, p = 0.041), diagnosis of degenerative spondylolisthesis (OR 10.5, p = 0.017), and > 7 instrumented levels (OR 2.6, p = 0.049) were significantly associated with high screw discrepancies.
Conclusion: The L-S2AI screw combines advantages of CIS and C-S2AI screws, which includes increased screw length, reduced lateral angulation, a low-profile screw head, ease of connection to proximal hardware, and the biomechanical advantage of a quadcortical purchase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s43390-021-00462-9 | DOI Listing |
Alzheimers Dement
December 2024
Amsterdam UMC, Amsterdam, Netherlands.
Background: The TMEM106B protein is critical for proper functioning of the endolysomal system, which is utilised by all cells to traffic and degrade molecular cargo. Genome-wide association studies identified a haplotype in the TMEM106B gene that is associated with increased risk for Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), and frontotemporal lobar degeneration with TAR DNA binding protein inclusions (FTLD-TDP). However, the causal variant that drives the association has thus far remained elusive.
View Article and Find Full Text PDFAm J Phys Med Rehabil
January 2025
Department of Physical Therapy, Akita University Graduate School of Health Sciences, 1-1-1 Hondo, Akita 010-8543, Japan.
Objective: To investigate whether the impacts of height increase on gastrocnemius muscle (GM) stiffness are greater in children with spastic cerebral palsy (CP) than in those with typical development (TD).
Design: This one-year cohort study enrolled children (CP, 23; TD, 23) who underwent two measurements conducted at entry and after one year. Lateral and medial GM-strain ratios representing muscle stiffness were obtained using elastography.
World J Orthop
December 2024
Department of Orthopaedic Surgery and Traumatology, Cantonal Hospital Sankt Gallen, Sankt Gallen 9007, Switzerland.
Background: When patients with a failed hip arthroplasty are unsuitable for reimplantation, Girdlestone resection arthroplasty (GRA) is a viable treatment option. We report on a patient who was treated with a GRA due to a periprosthetic infection. We discovered partial paralysis of the quadriceps muscle in this patient.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
This study presents a cutting-edge imaging technique for special unmanned vehicles (UAVs) designed to enhance tunnel inspection capabilities. This technique integrates ghost imaging inspired by the human visual system with lateral inhibition and variable resolution to improve environmental perception in challenging conditions, such as poor lighting and dust. By emulating the high-resolution foveal vision of the human eye, this method significantly enhances the efficiency and quality of image reconstruction for fine targets within the region of interest (ROI).
View Article and Find Full Text PDFOrthop Surg
December 2024
Department of Orthopaedics, The Fourth Medical Center, Chinese PLA General Hospital, Beijing, China.
Objective: There are many advantages to stabilize the posterior pelvic ring injuries with a transiliac-transsacral (TITS) screw percutaneously. To identify the correct entry point and insert a guidewire accurately for a TITS screw, we propose a method of specifying the optimal entry point, and introduce a technique of enabling freehand placement of a guidewire with fluoroscopic guidance.
Methods: In this retrospective study, 116 patients who underwent pelvic CT scans and pelvic lateral radiographs at our institution from January 2020 to April 2022 were enrolled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!