A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A dosimetric comparative analysis of Brainlab elements and Eclipse RapidArc for spine SBRT treatment planning. | LitMetric

. This is a dosimetric study comparing stereotactic body radiotherapy (SBRT) plans of spine tumors using Brainlab Elements Spine planning module against Eclipse RapidArc plans. Dose conformity, dose gradient, dose fall-off, and patient-specific quality assurance (QA) metrics were evaluated. Methods:Twenty patients were immobilized in supine position using half Vac-Lok. A prescription dose of 16 Gy in a single fraction was planned for Varian TrueBeam. Conformal arc plans were generated with Pencil beam (PB), MonteCarlo (MC) in Elements, and RapidArc with Acuros XB algorithm in Eclipse using identical treatment geometry.s. Eclipse, Elements PB, and Elements MC generated dosimetrically conformal plans having Inverse Paddick Conformity Index (IPCI) <1.3. All plans satisfied the dose constraints to target and OARs. Elements PB had a sharper gradient than Elements MC with average GI of 3.67(95% CI: 3.52-3.82) and 4.06 (95% CI: 3.93-4.20) respectively. Eclipse plans were more homogeneous with mean HI = 1.22 (95% CI: 1.20-1.23) that is lower than others. Average maximum clinical target volume (CTV) doses were higher in Elements MC with 22.31 Gy (95% CI: 21.87-22.74), while PB plans have 21.15 Gy (95% CI: 20.36-21.96), respectively. Elements MC and PB plans had lower average dose to 0.35 c.c. of spinal cord (D0.35cc) of 7.60 Gy (95% CI: 7.18-8.02) and 8.42 Gy (95% CI: 7.83-9.01). All plans had >95% points passing the gamma QA criteria at 3%/2 mm.. All treatment plans achieved clinically acceptable target coverage >95% and meet spinal cord dose limits. Smart optimization in Brainlab Elements spine module produced dosimetrically superior plans by better spinal cord sparing.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ac4f97DOI Listing

Publication Analysis

Top Keywords

brainlab elements
12
eclipse rapidarc
8
elements spine
8
spinal cord
8
elements
6
plans
6
dose
5
dosimetric comparative
4
comparative analysis
4
analysis brainlab
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!