NEAR: An artifact removal pipeline for human newborn EEG data.

Dev Cogn Neurosci

CIMeC, Center for Mind/Brain Sciences, University of Trento, Rovereto, Italy. Electronic address:

Published: April 2022

Electroencephalography (EEG) is arising as a valuable method to investigate neurocognitive functions shortly after birth. However, obtaining high-quality EEG data from human newborn recordings is challenging. Compared to adults and older infants, datasets are typically much shorter due to newborns' limited attentional span and much noisier due to non-stereotyped artifacts mainly caused by uncontrollable movements. We propose Newborn EEG Artifact Removal (NEAR), a pipeline for EEG artifact removal designed explicitly for human newborns. NEAR is based on two key steps: 1) A novel bad channel detection tool based on the Local Outlier Factor (LOF), a robust outlier detection algorithm; 2) A parameter calibration procedure for adapting to newborn EEG data the algorithm Artifacts Subspace Reconstruction (ASR), developed for artifact removal in mobile adult EEG. Tests on simulated data showed that NEAR outperforms existing methods in removing representative newborn non-stereotypical artifacts. NEAR was validated on two developmental populations (newborns and 9-month-old infants) recorded with two different experimental designs (frequency-tagging and ERP). Results show that NEAR artifact removal successfully reproduces established EEG responses from noisy datasets, with a higher statistical significance than the one obtained by existing artifact removal methods. The EEGLAB-based NEAR pipeline is freely available at https://github.com/vpKumaravel/NEAR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8800139PMC
http://dx.doi.org/10.1016/j.dcn.2022.101068DOI Listing

Publication Analysis

Top Keywords

artifact removal
24
newborn eeg
12
eeg data
12
removal pipeline
8
human newborn
8
eeg
8
eeg artifact
8
artifact
6
newborn
5
removal
5

Similar Publications

Importance: Functional near-infrared spectroscopy (fNIRS) is a noninvasive technique used to quantify prefrontal cortex (PFC) neuroexcitation. The PFC is involved in the decision to void, and dysfunction in the region has been associated with overactive bladder (OAB). This study demonstrates neuroexcitation differences in the brain region associated with the decision to void (prefrontal cortex) using noninvasive fNIRS.

View Article and Find Full Text PDF

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes.

View Article and Find Full Text PDF

Given that perioperative normothermia represents a quality parameter in pediatric anesthesia, numerous studies have been conducted on temperature measurement, albeit with heterogeneous measurement intervals, ranging from 30 s to fifteen minutes. We aimed to determine the minimum time interval for reporting of intraoperative core body temperature across commonly used measurement intervals in children. Data were extracted from the records of 65 children who had participated in another clinical study and analyzed using a quasibinomial mixed linear model.

View Article and Find Full Text PDF

Generating synthetic CT images from unpaired head and neck CBCT images and validating the importance of detailed nasal cavity acquisition through simulations.

Comput Biol Med

December 2024

Division of Obstructive Sleep Apnea Syndrome Diagnosis, School of Mechanical Engineering, College of Engineering, Yonsei University, Seoul, Republic of Korea; The Center for Hemodynamic Precision Medical Platform, Seoul, Republic of Korea. Electronic address:

Background And Objective: Computed tomography (CT) of the head and neck is crucial for diagnosing internal structures. The demand for substituting traditional CT with cone beam CT (CBCT) exists because of its cost-effectiveness and reduced radiation exposure. However, CBCT cannot accurately depict airway shapes owing to image noise.

View Article and Find Full Text PDF

Multi-scale perceptual modulation network for low-dose computed tomography denoising.

Quant Imaging Med Surg

December 2024

Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.

Background: Low-dose computed tomography (LDCT) reduces radiation exposure, but the introduced noise and artifacts impair its diagnostic accuracy. Convolutional neural networks (CNNs) are widely used for LDCT denoising, but they suffer from a limited receptive field. The use of a larger kernel size can enlarge the receptive field and boost model performance; however, the computational cost of the model greatly increases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!