A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Association between coronary artery calcium score and in-stent restenosis after drug-eluting stent implantation. | LitMetric

Background: Coronary artery calcium (CAC) is a modifiable contributor of in-stent restenosis (ISR), but quantitative analyses using a noninvasive approach are limited. We aimed to investigate the associations between CAC score derived from ECG-gated coronary computed tomography angiography (CCTA) or non-gated non-contrast chest computed tomography (NCCT) and ISR.

Methods: We included 368 lesions in 194 patients with coronary drug-eluting stent implantations in final analyses. CAC was quantified using the Agatston score. Primary endpoint was ISR, defined as lumen diameter stenosis over 50% at the stent segment or its proximal or distal edges (5-mm segments adjacent to the stent), at angiographic follow-up.

Results: The CAC scores in either CCTA/2.5 mm group (r = 0.7702; P < 0.0001) or NCCT/5 mm group (r = 0.7105; P < 0.0001) were both correlated with in-stent diameter stenosis. The receiver-operating characteristic curve analysis identified a CAC score >245 in CCTA/2.5 mm group as the optimal ISR cutoff (sensitivity, 60.0%; specificity, 83.7%; area under the curve, 0.744; P < 0.001), and >209 in NCCT/5 mm group (sensitivity, 46.7%; specificity, 91.9%; area under the curve, 0.704; P < 0.001). Multivariable logistic regression models indicated a CAC score >245 in CCTA/2.5 mm group and >209 in NCCT/5 mm group independently associated with an 8.46- and 21.89-fold increase in ISR, respectively (all P < 0.01).

Conclusions: Either a CAC score >245 in CCTA/2.5 mm or >209 in NCCT/5 mm was significantly associated with increased risk in ISR.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MCA.0000000000001124DOI Listing

Publication Analysis

Top Keywords

ccta/25 group
12
ncct/5 group
12
p 245 ccta/25
12
coronary artery
8
artery calcium
8
in-stent restenosis
8
drug-eluting stent
8
computed tomography
8
area curve
8
>209 ncct/5
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!