Purpose: This study is aimed to evaluate the impact of catheter contact angle on lesion formation and durability of pulmonary vein isolation (PVI).

Methods: Both in vitro experiment and retrospective observational study were conducted. For in vitro experiment, radiofrequency lesions were created on explanted swine hearts in three different catheter contact angles (0°, 45°, and 90°). In the retrospective observational study, we assessed patients who had undergone repeat catheter ablation due to atrial fibrillation recurrence after initial PVI. When pulmonary vein (PV) reconnection was observed, we analyzed the previous ablation points within and without the gap area. The gap areas were where ablation had changed the PV activation sequence or eliminated the PV potential in the repeat session.

Results: In the in vitro experiment, lesion width was the smallest (5.3 ± 0.4 mm) in perpendicular contact compared to 0° (vs 5.8 ± 0.5 mm, p = 0.040) and 45° (vs 6.4 ± 0.4 mm, p < 0.001). In the retrospective observational study, we assessed 666 tags of 16 patients with PV reconnections, and 60 tags were in the gap area. Tags in the gap area had longer interlesion distance (odds ratio [OR] 1.49, p < 0.001), greater contact force variability (OR 1.03, p = 0.008), and higher rate of perpendicular contact (OR 3.26, p < 0.001) on multivariate analysis.

Conclusions: Perpendicular contact was associated with a smaller lesion and higher rate of PV reconnection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470614PMC
http://dx.doi.org/10.1007/s10840-022-01131-1DOI Listing

Publication Analysis

Top Keywords

catheter contact
12
pulmonary vein
12
vitro experiment
12
impact catheter
8
contact angle
8
angle lesion
8
lesion formation
8
formation durability
8
durability pulmonary
8
vein isolation
8

Similar Publications

A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-months success rates.

Heart Rhythm

January 2025

Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Background: Focal pulsed-field ablation (F-PFA) integrated in electroanatomical mapping (EAM) systems allows tailored lesion sets in patients with atrial fibrillation (AF).

Objective: To determine feasibility, safety and 6-months outcome of F-PFA for a tailored substrate-based catheter ablation (CA) approach in patients with AF and advanced atrial substrate.

Methods: Consecutive patients with AF and advanced atrial substrate treated by a F-PFA system (Cardiofocus) through contact-force sensing catheters integrated in EAM systems were prospectively enrolled.

View Article and Find Full Text PDF

Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).

View Article and Find Full Text PDF

Background/objectives: Very high-power and short-duration (vHPSD) ablation with QDOT MICRO™ facilitates speedy and safe ablation for pulmonary vein isolation. A brief time interval between ablating two neighboring sites with vHPSD may potentially influence the size and geometry of the lesions. This study evaluates lesion formation when delivering adjacent applications using vHPSD at various inter-lesion times (ILTs).

View Article and Find Full Text PDF

Catheter-associated urinary tract infection (CAUTI) induced by rapid bacterial colonization and biofilm formation on urinary catheters is a key issue that urgently needs to be addressed. To prevent CAUTI, many contact-killing, non-leaching coatings have been developed for the surfaces of silicone catheters. However, due to the chemical inertness of the silicone substrate, most current coatings lack adhesion and are unstable under external forces.

View Article and Find Full Text PDF

Tunneled Pleural Catheters: An Effective Nonsurgical Alternative for Nonexpandable Lung in Chronic Pleural Infection.

J Bronchology Interv Pulmonol

January 2025

Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School.

Background: Open window thoracostomy (OTW) is the standard of care for debilitated patients with chronic pleural infection and nonexpandable lungs (NEL) who are not candidates for major surgical intervention. Tunneled pleural catheters (TPC) offer tremendous treatment potential in this setting based on their efficacy in malignant pleural effusion and NEL. We aim to assess the efficacy, safety, and health care utilization of TPC in this setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!