What are the risk factors for complications after combined injury of the pelvic ring and acetabulum?

Eur J Orthop Surg Traumatol

Department of Orthopedic Surgery, University of Alabama at Birmingham, Orthopedic Specialties Building, 1313 13th Street South, Birmingham, Al, 35205, USA.

Published: February 2023

Purpose: Combined acetabular and pelvic ring injuries represent a unique subset of pelvic trauma and little is known regarding their complications and outcomes. We sought to further evaluate these injury patterns and quantify their outcomes.

Methods: A retrospective review at a single level 1 trauma center was performed on all patients with operatively treated combined ring and acetabulum injuries during a seven-year period. Main outcome measurements include all-cause complication including residual neurologic deficit, deep infection, conversion to total hip arthroplasty, deep venous thrombosis and mortality.

Results: Seventy operatively treated combined ring and acetabulum patients with one-year follow-up were reviewed. The overall complication rate was 44%. Hip dislocation occurred in 40% of the cohort and was significantly associated with residual neurologic deficit and all-cause complication. Angiography with embolization was not associated with an increased rate of deep infection. Open acetabular approaches had a significantly higher complication rate compared to percutaneous procedures. Delay to definitive fixation greater than 36 h trended toward but did not reach association with all complications.

Conclusion: Combined injuries to the acetabulum and pelvic ring have high rates of complications. No individual fracture patterns were identified as risk factors, but hip dislocation was associated with an increased rate of complications. When possible, percutaneous reduction and fixation of acetabular fractures and early definitive fracture fixation lead to lower rates of complications. Use of angiography with embolization appears to be safe and does not increase the risk of infection or other complications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-021-03189-5DOI Listing

Publication Analysis

Top Keywords

pelvic ring
12
risk factors
8
operatively treated
8
treated combined
8
combined ring
8
ring acetabulum
8
all-cause complication
8
residual neurologic
8
neurologic deficit
8
deep infection
8

Similar Publications

Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.

View Article and Find Full Text PDF

Abdominal wall repair in adults with bladder exstrophy is challenging. We present a case of a 46-year-old woman with bladder exstrophy presenting with a large midline incisional hernia associated with a 13-cm hypoplasia of both pubic rami that precluded fixation of any abdominal mesh. A two-stage approach was adopted.

View Article and Find Full Text PDF

Case: A 35-year-old man with morbid obesity sustained an ultra-low velocity (ULV) rotational knee dislocation secondary to a fall from standing. The patient was successfully treated using a subcutaneous knee-spanning internal fixator, the "INFIX" technique, which has previously been described for pelvic ring injuries.

Conclusion: This novel technique maintained the stable reduction of an ULV knee dislocation in a patient with morbid obesity until adequate healing was achieved.

View Article and Find Full Text PDF

Background: It is known that fractures of the pelvic ring and acetabulum in work-related accidents are associated with long periods of incapacity to work, a high rate of reduction in earning capacity (MdE) and high costs for pension/severance pay.

Objective: Investigation of changes in pension claims and costs from 2013 to 2019 after isolated fractures of the pelvic ring and acetabulum in work-related accidents in Germany.

Material And Methods: For all patients from the German Social Accident Insurance (DGUV) registry with isolated fractures of the pelvic ring or acetabulum in work-related accidents, linear trend analyses were carried out among others for the proportion of MdE ≥20%, the proportion of cases receiving pension/severance pay and total costs for pension/severance pay from 2013 to 2019.

View Article and Find Full Text PDF

Migrated intra-uterine device to infra-umbilical skin: a rare case report.

BMC Womens Health

December 2024

Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.

Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!