Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study aims to investigate whether wearing a filtering facepiece class 3 respirators with personal protective equipment (FPP3/PPE) during work in the intensive care unit (ICU) affects the blood saturation (SpO2), the heart rate (HR), and the well-being of health care workers (HCWs). This preliminary study included a group of 21 volunteers (including 16 females (76%), with a median age of 23 years). Each worker served as his own control and performed the test two times: they wore the FFP3/PPE and did not wear it for a three-hour shift in the ICU. The working with an FFP3/PPE compared to not working with an FFP3/PPE caused a significant, but within normal ranges, influence on the level of SpO2 with a mean decrease of - 1.43%. The highest reduction in the SpO2 was - 2.29% and occurred after 150 min of work. All of the score scales of the well-being markers increased consecutively but moderately during the shift while wearing the FFP3/PPE. We assume that a 3-h shift rhythm is a safe and reliable solution, i.e., three hours of working in the FFP3/PPE in the ICU, followed by rest or working without an FFP3/PPE.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8789906 | PMC |
http://dx.doi.org/10.1038/s41598-022-05319-3 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!