With the increased use of X-ray imaging for patient alignment in external beam radiation therapy, particularly with cone-beam computed tomography (CBCT), the additional dose received by patients has become of greater consideration. In this study, we analysed the radiation dose from CBCT for clinical lung radiotherapy and assessed its relative contribution when combined with radiation treatment planning for a variety of lung radiotherapy techniques. The Monte Carlo simulation program ImpactMC was used to calculate the 3D dose delivered by a Varian TrueBeam linear accelerator to patients undergoing thorax CBCT imaging. The concomitant dose was calculated by simulating the daily CBCT irradiation of ten lung cancer patients. Each case was planned with a total dose of 50-60 Gy to the target lesion in 25-30 fractions using the 3DCRT or IMRT plan and retrospectively planned using VMAT. For each clinical case, the calculated CBCT dose was summed with the planned dose, and the dose to lungs, heart, and spinal cord were analysed according to conventional dose conformity metrics. Our results indicate greater variations in dose to the heart, lungs, and spinal cord based on planning technique, (3DCRT, IMRT, VMAT) than from the inclusion of daily cone-beam imaging doses over 25-30 fractions. The average doses from CBCT imaging per fraction to the lungs, heart and spinal cord were 0.52 ± 0.10, 0.49 ± 0.15 and 0.39 ± 0.08 cGy, respectively. Lung dose variations were related to the patient's size and body composition. Over a treatment course, this may result in an additional mean absorbed dose of 0.15-0.2 Gy. For lung V5, the imaging dose resulted in an average increase of ~ 0.6% of the total volume receiving 5 Gy. The increase in V20 was more dependent on the planning technique, with 3DCRT increasing by 0.11 ± 0.09% with imaging and IMRT and VMAT increasing by 0.17 ± 0.05% and 0.2 ± 0.06%, respectively. In this study, we assessed the concomitant dose for daily CBCT lung cancer patients undergoing radiotherapy. The additional radiation dose to the normal lungs from daily CBCT was found to range from 0.15 to 0.2 Gy when the patient was treated with 25-30 fractions. Consideration of potential variation in relative biological effectiveness between kilovoltage imaging and megavoltage treatment dose was outside the scope of this study. Regardless of this, our results show that the assessment of imaging dose can be incorporated into the treatment planning process and the relative effect on overall dose distribution was small compared to the difference among planning techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-022-01105-7DOI Listing

Publication Analysis

Top Keywords

dose
19
lung radiotherapy
12
treatment planning
12
daily cbct
12
25-30 fractions
12
spinal cord
12
daily cone-beam
8
imaging
8
cbct
8
radiation dose
8

Similar Publications

Efficacy and safety of daprodustat in patients on peritoneal dialysis in the ASCEND-D trial.

Nephrol Dial Transplant

November 2024

Department of Medicine and Nephrology, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City, Mexico.

Background And Hypothesis: Daprodustat, an oral hypoxia-inducible factor prolyl hydroxylase inhibitor, is approved for treatment of anemia in dialysis patients with CKD in some parts of the world. This subgroup analysis examined the efficacy and safety of daprodustat versus darbepoetin alfa in patients with anemia of CKD undergoing peritoneal dialysis (PD).

Methods: ASCEND-D (NCT02879305) was an open-label, Phase 3 trial; patients with CKD were randomized to daprodustat daily and epoetin alfa (HD patients) or darbepoetin alfa (PD patients).

View Article and Find Full Text PDF

Introduction: Retatrutide is a novel triple hormone receptor agonist which has shown great promise in tackling obesity in preliminary trials. We did this systematic review and meta-analysis to pool the results of all available trials and ascertain its safety and efficacy in the treatment of obesity.

Material And Methods: A literature search was conducted in PubMed, Cochrane Central and Embase using appropriate search terms and randomized control trials (RCTs) were identified which reported the safety and efficacy of retatrutide.

View Article and Find Full Text PDF

Background And Purpose: Radiation-induced lymphopenia (RIL) may be associated with a worse prognosis in pancreatic cancer. This study aimed to develop a normal tissue complication probability (NTCP) model to predict severe RIL in patients with pancreatic cancer undergoing concurrent chemoradiotherapy (CCRT).

Materials And Methods: We reviewed pancreatic cancer patients treated at our facility for model training and internal validation.

View Article and Find Full Text PDF

When a difficult airway is anticipated, awake tracheal intubation can be considered. Usually, low doses of sedatives are administered during this procedure for minimal sedation and anxiolysis, such as midazolam and remifentanil. The newly developed ultra-short-acting benzodiazepine remimazolam has a pharmacokinetic profile that is more suitable for titration during awake tracheal intubation than the long-acting midazolam.

View Article and Find Full Text PDF

Purpose: Research suggests that insulin resistance (IR) is associated with acute ischemic stroke (AIS) and depression. The use of insulin-based IR assessments is complicated. Therefore, we explored the relationship between four non-insulin-based IR indices and post-stroke depression (PSD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!