There are advocates of both two-dimensional (2D) and three-dimensional (3D) templating methods for planning total hip replacement. The aim of this study was to compare the accuracy of implant size prediction when using 2D and 3D templating methods for total hip arthroplasty, as well as to compare the inter- and intra-observer reliability in order to determine whether currently available methods are sufficiently reliable and reproducible. Medline, EMBASE and PubMed were searched to identify studies that compared the accuracy of 2D and 3D templating for total hip replacement. Results were screened using the PRISMA flowchart and included studies were assessed for their level of evidence using the Oxford CEBM criteria. Non-randomized trials were critically appraised using the MINORS tool, whilst randomized trials were assessed using the CASP RCT checklist. A series of meta-analyses of the data for accuracy were also conducted. Ten studies reported that 3D templating is an accurate and reliable method of templating for total hip replacement. Six studies compared 3D templating with 2D templating, all of which concluded that 3D templating was more accurate, with three finding a statistically significant difference. The meta-analyses showed that 3D CT templating is the most accurate method. This review supports the hypothesis that 3D templating is an accurate and reliable method of preoperative planning, which is more accurate than 2D templating for predicting implant size. However, further research is needed to ascertain the significance of this improved accuracy and whether it will yield any clinical benefit.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788155PMC
http://dx.doi.org/10.1530/EOR-21-0060DOI Listing

Publication Analysis

Top Keywords

total hip
20
hip replacement
16
templating accurate
16
templating
12
templating methods
12
accuracy templating
8
methods planning
8
implant size
8
studies compared
8
templating total
8

Similar Publications

Exploratory analysis of gait mechanics in farmers.

J Occup Environ Hyg

January 2025

Department of Kinesiology & Health Promotion, University of Kentucky, Lexington, Kentucky.

Farmers may be at a higher risk of developing hip osteoarthritis (OA) due to the high demands of their occupation. To the authors' knowledge, the gait patterns of farmers that may be associated with hip joint degeneration have yet to be analyzed. Therefore, this study compares gait mechanics between farmers and non-farmers (controls).

View Article and Find Full Text PDF

Patients with radiographic axial spondyloarthritis (r-axSpA) experience a higher prevalence of fragility fractures, though the pathophysiology of osteoporosis associated with this disease remains poorly understood. The objective of this study was to evaluate the histomorphometric data in r-axSpA patients. Male r-axSpA patients up to 55 years old were enrolled in this cross-sectional study.

View Article and Find Full Text PDF

Purpose: Studies evaluating the long-term survival rate, patient satisfaction, and conversion to total hip arthroplasty (THA) are limited. The aim of this study was to evaluate satisfaction and hip survival at a minimum 10-year follow-up in patients following hip arthroscopy for femoroacetabular impingement syndrome (FAIS).

Methods: A total of 164 patients underwent hip arthroscopy for FAIS between 2007 and 2012; of these, 76 (49 men and 27 women; mean age, 40.

View Article and Find Full Text PDF

Aseptic loosening (AL) of artificial hip joints is the most common complication following hip replacement surgery. A total of eight patients diagnosed with AL following total hip arthroplasty (THA) undergoing total hip replacement and eight control patients diagnosed with avascular necrosis of femoral head (ANFH) or femoral neck fracture undergoing THA were enrolled. The samples of the AL group were from synovial tissue surrounding the lining/head/neck of the prosthesis, and the samples of the control group were from the synovium in the joint cavity.

View Article and Find Full Text PDF

Sleep apnea is a global public health concern, but little research has examined this issue in low- and middle-income countries, including Samoa. The purpose of this study was to examine the sample prevalence and characteristics of sleep apnea using a validated home sleep apnea device (WatchPAT, Itamar) and explore factors that may influence sleep health in the Samoan setting. This study used data collected through the ("Good Health") study, which investigated the impact of the body mass index (BMI)-associated genetic variant rs373863828 in on metabolic traits in Samoan adults (sampled to overrepresent the obesity-risk allele of interest).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!