A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Echocardiographic guidance for HARPOON beating-heart mitral valve repair. | LitMetric

The HARPOON mitral valve (MV) repair system has been shown to safely and effectively treat a degenerative MV prolapse with transventricular implantation of artificial cords on a beating heart. The low profile system is introduced and precisely steered under 3D TEE guidance towards the previously selected target on a prolapsing MV segment. It allows puncture and deployment of a knot on the leaflet. The procedure is repeated until desired number of knots are implanted and the cords are optimally tensioned to restore coaptation. The cords are then tied down on the epicardium over a felt pledget. State of the art echocardiographic imaging is a crucial part of the procedure. It starts from patients screening, pre-procedural analysis and planning, access selection, navigation, deployment, optimal cordal tensioning, and final MV assessment and is continued during the follow-up assessment. This article illustrates the specific echocardiographic aspects of the HARPOON procedure including 2D and advanced 3D TEE techniques. The echocardiographic protocol was developed based on initial experience in 60 procedures. Detailed training of the echocardiographer and surgical team, is mandatory to achieve excellent results of this procedure, being now introduced in the clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788012PMC
http://dx.doi.org/10.1093/ehjci/jeab044DOI Listing

Publication Analysis

Top Keywords

mitral valve
8
valve repair
8
echocardiographic
4
echocardiographic guidance
4
guidance harpoon
4
harpoon beating-heart
4
beating-heart mitral
4
repair harpoon
4
harpoon mitral
4
repair system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!