Around 90% of the energy requirement for urban water systems management is for heating domestic tap water. In addition, the energy content of wastewater is mainly in the form of heat (85%). Hence, there is an obvious interest in recovering a large portion of this heat. However, city-wide scenario analyses that evaluate heat recovery at various locations while considering impacts on wastewater treatment plant (WWTP) performance are currently very limited. This study presents a comprehensive model-based city-wide evaluation considering four different heat recovery locations (appliance, household, precinct and WWTP effluent) for a Swedish city with varying degrees of implementation using an uncertainty-based approach. Results show that heat recovery at the appliance level, with heat exchangers installed at 77% of the showers at domestic households, leads to a mean energy recovery of 127 MWh/day with a 0.25 °C reduction in mean WWTP inlet temperature compared to the default case without heat recovery. The highest mean temperature reduction compared to the default case is 1.5 °C when heat is recovered at the precinct level for 77% of the domestic wastewater flow rate. Finally, the impact on WWTP nitrification capacity is negligible in this case due to its large existing capacity and design.