A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical influence of thread form on stress distribution over short implants (≤6 mm) using finite element analysis. | LitMetric

Biomechanical influence of thread form on stress distribution over short implants (≤6 mm) using finite element analysis.

Biomed Tech (Berl)

Engineering Fundamental Teaching and Training Centre, South China Agricultural University, Guangzhou, Guangdong Province, China.

Published: February 2022

The macro and micro design is essential to the biomechanical performance of a short implant. In this study, the implant thread parameters of short implants used in edentulous maxillae will be discussed. The aim of the study is to analyse biomechanical distinctions in different thread parameters over short implants by applying the vertical or oblique load of 130 N on dental prosthesis. A 6*5 mm implant will be used in posterior maxillae arch, where the molar region locates. The CAD model has been assembled by three parts, a crown, an implant system and a jaw. By applying the vertical or oblique load to the crown, the Von-Mises stresses of cortical bone and trabecular bone will be evaluated in pairs along the lines v1-v2 & a1-a2. The results showed that the reverse buttress thread would induce more stresses in cancellous bone whereas the buttress did the opposite. The trapezoidal thread (V-thread) is more favourable than the reverse buttress thread in accordance to the FEA result. The rectangle threads will induce more uneven stresses in cancellous bones.

Download full-text PDF

Source
http://dx.doi.org/10.1515/bmt-2020-0215DOI Listing

Publication Analysis

Top Keywords

short implants
12
thread parameters
8
parameters short
8
applying vertical
8
vertical oblique
8
oblique load
8
buttress thread
8
stresses cancellous
8
thread
6
biomechanical influence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!