High-frequency convex array transducer, featuring both high spatial resolution and wide field of view, has been successfully developed for ophthalmic imaging. To further expand its application range to small animals' imaging, this work develops a high-frequency microconvex array transducer possessing smaller aperture size and wider scanning angle. This transducer featured 128 array elements arranged in a curvilinear 2-2 piezoelectric composite configuration, yielding a maximum view angle of 97.8°. The array was composed of two front matching layers, a nonconductive backing layer, and a customized flexible circuit that electrically connected array elements to coaxial cables. The center frequency and the -6-dB fractional bandwidth were about 18.14 MHz and 69.15%, respectively. The image of a tungsten wire phantom resulted in approximately 62.9- [Formula: see text] axial resolution and 121.3- [Formula: see text] lateral resolution. The image of the whole kidney of a rat as well as its internal arteries was acquired in vivo, demonstrating the imaging capability of the proposed high-frequency microconvex array transducers for small animals' imaging applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2022.3146309 | DOI Listing |
Eur J Pediatr
August 2024
Neonatal Intensive Care Unit, Women's and Children's Health Department, University Hospital of Modena, Via del Pozzo, 41124, Modena, Italy.
The quality of cranial ultrasound has improved over time, with advancing technology leading to higher resolution, faster image processing, digital display, and back-up. However, some brain lesions may remain difficult to characterize: since higher frequencies result in greater spatial resolution, the use of additional transducers may overcome some of these limitations. The very high-frequency transducers (18-5 MHz) are currently employed for small parts and lung ultrasound.
View Article and Find Full Text PDFUltrasound J
February 2024
Intensive Care Medicine Department, University Hospital of Heraklion, University of Crete, Voutes, 71110, Heraklion, Crete, Greece.
Introduction And Objectives: Thoracic ultrasound (TUS) has been established as a powerful diagnostic and monitoring tool in the Intensive Care Unit (ICU). However, studies outside the critical care setting are scarce. The aim of this study was to investigate the value of TUS for hospitalized or ambulatory community patients.
View Article and Find Full Text PDFFront Vet Sci
November 2023
Department of Veterinary Science, University of Turin, Torino, Italy.
Introduction: This study aimed to investigate the use of ultrasonography for verifying feeding tube placement in hospitalized cats compared with radiographic evaluation.
Methods: This prospective investigation was performed on client-owned cats. The position of the feeding tube was checked using right lateral thoracic radiography and ultrasonography.
IEEE Trans Ultrason Ferroelectr Freq Control
June 2022
High-frequency convex array transducer, featuring both high spatial resolution and wide field of view, has been successfully developed for ophthalmic imaging. To further expand its application range to small animals' imaging, this work develops a high-frequency microconvex array transducer possessing smaller aperture size and wider scanning angle. This transducer featured 128 array elements arranged in a curvilinear 2-2 piezoelectric composite configuration, yielding a maximum view angle of 97.
View Article and Find Full Text PDFJ Feline Med Surg
August 2020
Department of Veterinary Medical Sciences, University of Bologna, Bologna, Italy.
Objectives: The aim of this study was to evaluate the relationship between the ultrasonographic (US) diffuse honeycomb pattern (HCP) of the spleen and a pathological diagnosis in cats, and to assess the influence of transducer type on HCP visualisation.
Methods: Abdominal ultrasounds of cats with an HCP were reviewed and splenic size, shape, margination, other parenchymal alterations and splenic hilar lymphadenopathy were recorded. When applicable, images acquired with high-frequency linear and curvilinear transducers were compared to determine if an HCP was more frequently demonstrated on high-resolution images.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!