J Electr Bioimpedance
Medical Information Technology, RWTH Aachen University, Aachen, Germany.
Published: January 2021
Volume measurement is beneficial in left ventricular assist device (LVAD) therapy to quantify patient demand. In principle, an LVAD could provide a platform that allows bioimpedance measurements inside the ventricle without requiring additional implants. Conductance measured by the LVAD can then be used to estimate the ventricular radius, which can be applied to calculate ventricular volume. However, established methods that estimate radius from conductance require elaborate individual calibration or show low accuracy. This study presents two analytical calculation methods to estimate left ventricular radius from conductance using electric field theory. These methods build on the established method of Wei, now considering the dielectric properties of muscle and background tissue, the refraction of the electric field at the blood-muscle boundary, and the changes of the electric field caused by the measurements. The methods are validated in five glass containers of different radius. Additional bioimpedance measurements are performed in in-vitro models that replicate the left ventricle's shape and conductive properties. The proposed analytical calculation methods estimate the radii of the containers and the in-vitro models with higher accuracy and precision than Wei's method. The lead method performs excellently in glass cylinders over a wide range of radii (bias: 1.66%-2.48%, limits of agreement < 16.33%) without calibration to specific geometries.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8713389 | PMC |
http://dx.doi.org/10.2478/joeb-2021-0015 | DOI Listing |
Nano Converg
January 2025
Bendable Electronics and Sustainable Technologies (BEST) Group, Electrical and Computer Engineering Department, Northeastern University, Boston, MA, 02115, USA.
The intriguing way the receptors in biological skin encode the tactile data has inspired the development of electronic skins (e-skin) with brain-inspired or neuromorphic computing. Starting with local (near sensor) data processing, there is an inherent mechanism in play that helps to scale down the data. This is particularly attractive when one considers the huge data produced by large number of sensors expected in a large area e-skin such as the whole-body skin of a robot.
View Article and Find Full Text PDFLangmuir
January 2025
School of Minerals Processing and Bioengineering, Central South University, Changsha 410083, P. R. China.
Understanding the interfacial interaction mechanisms between oil and minerals is of vital importance in the applications of petroleum production and environmental protection. In this work, the interactions of dodecane with mica and calcite in aqueous media were investigated by using the drop probe technique based on atomic force microscopy. For the dodecane-mica interactions, the electrical double layer (EDL) repulsion dominated in 10 mM NaCl solution, and a higher pH facilitated the detachment of dodecane.
View Article and Find Full Text PDFJ Phys Chem A
January 2025
School of Applied Science and Humanities, Haldia Institute of Technology, ICARE Complex, Haldia 721657, India.
This study explores the reactivity of a new intermolecular P/B frustrated Lewis pair in the context of dinitrogen activation through a push-pull mechanism. The ab initio molecular dynamics model known as atom-centered density matrix propagation plays a pivotal role in elucidating the weakly associated encounter complex. In-depth analysis, mainly through intrinsic reaction coordinate calculations, supports a single-step mechanism.
View Article and Find Full Text PDFBioelectromagnetics
January 2025
Seibersdorf Labor GmbH, Seibersdorf, Austria.
The electrical conductivity of human tissues is a major source of uncertainty when modelling the interactions between electromagnetic fields and the human body. The aim of this study is to estimate human tissue conductivities in vivo over the low-frequency range, from 30 Hz to 1 MHz. Noninvasive impedance measurements, medical imaging, and 3D surface scanning were performed on the forearms of ten volunteer test subjects.
View Article and Find Full Text PDFNat Mater
January 2025
Mechanisms of Morphogenesis Lab, Gulbenkian Institute of Science (IGC), Oeiras, Portugal.
Directed collective cell migration is essential for morphogenesis, and chemical, electrical, mechanical and topological features have been shown to guide cell migration in vitro. Here we provide in vivo evidence showing that endogenous electric fields drive the directed collective cell migration of an embryonic stem cell population-the cephalic neural crest of Xenopus laevis. We demonstrate that the voltage-sensitive phosphatase 1 is a key component of the molecular mechanism, enabling neural crest cells to specifically transduce electric fields into a directional cue in vivo.