Objectives: The purpose of this in vitro study was to investigate the effects of various surface treatment methods on the shear bond strength of self-adhesive resin cement to polymer-infiltrated materials.

Materials And Methods: One hundred twenty-eight polymer-infiltrated specimens (n = 32) for four different computer aided design-computer-aided manufacturing (CAD-CAM) materials, polyether ether ketone (PEEK) (PE), polyether ketone ketone (PEKK) (PK), composite resin nanoceramic (Cerasmart) (CS), and polymer-infiltrated ceramic network (PICN) (VITA ENAMIC) (VE) were milled from CAD-CAM blocks. They were divided into two groups (n = 16) in terms of surface treatments: airborne-particle abraded (AA) or silica-coated (SC) and two subgroups (n = 8) according to adhesive application or no adhesive. The surface roughness, contact angle, and shear bond strength (SBS) values of specimens were measured. Data were analyzed with Shapiro-Wilk test, the generalized linear models' method, and Bonferroni corrected t test (α ˂ 0.05).

Results: No statistically significant differences were found between the groups in terms of surface roughness and SBS values (P > 0.05). A statistically significant effect of the main adhesive interaction on the bond strength was found independent of the material and surface treatments (P < 0.001). While the average bond strength of the non-adhesive was 4.9 MPa, the average of the adhesive applied was 9.1 MPa. On the other hand, there is a statistically significant difference between the means of the contact angle values (P ˂ 0.001). While the highest mean contact angle value was 117.1 ± 14.8° obtained from the non-adhesive PK in the AA group, the lowest mean contact angle value 22.6 ± 4.3° was obtained from the VE without adhesive in the SC group.

Conclusions: Roughness and SBS values were similar between groups after surface treatments. Adhesive application increased the SBS values. Surface treatments were found to have an effect on the contact angle.

Clinical Relevance: Since the AA and SC surface treatments used in the study show similar bond strength values, the Cojet system, which is more practical and easier to use, can be preferred as an alternative to AA after restoration production with CAD-CAM as a chairside.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-021-04348-yDOI Listing

Publication Analysis

Top Keywords

bond strength
16
effects surface
8
shear bond
8
terms surface
8
surface treatments
8
surface roughness
8
sbs values
8
surface
6
evaluation effects
4
surface modification
4

Similar Publications

We report a direct application of the molecular tailoring approach-based (MTA-based) method to calculate the individual hydrogen bond (HB) energy in molecular crystal. For this purpose, molecular crystals of nitromalonamide (NMA) and salicylic acid (SA) were taken as test cases. Notably, doing a correlated computation using a large molecular crystal structure is difficult.

View Article and Find Full Text PDF

Sustainable pavement is essential for country development, offering durable, environmentally friendly, and cost-effective infrastructure. For Malaysia, sustainable pavement supports Sustainable Development Goals (SDGs) 9 and 11 while addressing road deterioration caused by increasing traffic volumes and loads. This deterioration shortens pavement service life and necessitates frequent maintenance, driving the need for innovative solutions.

View Article and Find Full Text PDF

In response to the rotary ploughing equipment in the stubble land to implement protective operations, the stubble is large in number and strong in toughness, not easy to crush, resulting in rotary ploughing equipment to produce entanglement and increased resistance to rotary ploughing and other issues. In this study, researchers designed a bionic rotary tillage blade (B-RTB) based on the bionic structural equations of the Marmota claw. A straw-soil complex shear performance test was conducted to investigate the effect of straw on soil shear strength.

View Article and Find Full Text PDF

Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.

Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.

View Article and Find Full Text PDF

An Automated Workflow to Discover the Structure-Stability Relations for Radiation Hard Molecular Semiconductors.

J Am Chem Soc

January 2025

Institute of Materials for Electronics and Energy Technology (i-MEET), Department of Materials Science and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Martensstraße 7, 91058 Erlangen, Germany.

Article Synopsis
  • Emerging photovoltaics require radiation-hard materials for use in outer space, but predicting their resilience to high-energy radiation is currently a challenge.
  • The research combines lab automation and machine learning to rapidly identify and test over 130 organic hole transport materials, assessing their stability under UVC light exposure.
  • Findings reveal that materials with fused aromatic rings are more stable, while certain chemical groups negatively impact stability, providing valuable insights for future molecular design in creating durable semiconductors.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!