Percutaneous left atrial appendage (LAA) occlusion is increasingly performed in patients with atrial fibrillation and long-term contraindications for anticoagulation. Our aim was to evaluate the effects of LAA occlusion with the Watchman device on the geometry of the LAA orifice and assess its impact on the adjacent left upper pulmonary vein (LUPV) hemodynamics. We included 50 patients who underwent percutaneous LAA occlusion with the Watchman device and had acceptable three-dimensional transesophageal echocardiography images of LAA pre- and post-device placement. We measured offline the LAA orifice diameters in the long axis, and the minimum and maximum diameters, circumference, and area in the short axis view. Eccentricity index was calculated as maximum/minimum diameter ratio. The LUPV peak S and D velocities pre- and post-procedure were also measured. Patients were elderly (mean age 76 ± 8 years), 30 (60%) were men. There was a significant increase of all LAA orifice dimensions following LAA occlusion: diameter 1 (pre-device 18.1 ± 3.2 vs. post-device 21.5 ± 3.4 mm, p < 0.001), diameter 2 (20.6 ± 3.9 vs. 22.1 ± 3.6 mm, p < 0.001), minimum diameter (17.6 ± 3.1 vs. 21.3 ± 3.4 mm, p < 0.001), maximum diameter (21.5 ± 3.9 vs. 22.4 ± 3.6 mm, p = 0.022), circumference (63.6 ± 10.7 vs. 69.6 ± 10.5 mm, p < 0.001), and area (3.1 ± 1.1 vs. 3.9 ± 1.2 cm, p < 0.001). Eccentricity index decreased after procedure (1.23 ± 0.16 vs. 1.06 ± 0.06, p < 0.001). LUPV peak S and D velocities did not show a significant difference (0.29 ± 0.15 vs. 0.30 ± 0.14 cm/s, p = 0.637; and 0.47 ± 0.19 vs. 0.48 ± 0.20 cm/s, p = 0.549; respectively). LAA orifice stretches significantly and it becomes more circular following LAA occlusion without causing a significant impact on the LUPV hemodynamics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10554-022-02525-y | DOI Listing |
Background Stroke is a major cause of death and disability globally, with different stroke burdens in different regions. This paper reviews the epidemiology of stroke in Asia. Summary There is a wide range in age and sex-standardised stroke incidence, highest in China, lowest in Bhutan.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
December 2024
Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Introduction: Intracardiac echocardiography (ICE) is an essential imaging modality for electrophysiology procedures, allowing intraprocedural monitoring, real-time catheter manipulation guidance, and visualization of complex anatomic structures. Four-dimentional (4D) ICE is the next stage in the evolution of the technology, permitting 360° rotation of the imaging plane, simultaneous multiplanar imaging, and volumetric acquisition, similar to transesophageal echocardiography (TEE). In this study, we report our experience with a novel 4D ICE catheter (NuVision, Biosense Webster) in structural electrophysiology procedures and difficult ventricular ablations in a swine preclinical model.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, University Heart Center Lübeck, Lübeck, Germany.
Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.
Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.
Eur Heart J Case Rep
December 2024
Electrophysiology Department, Rede D'Or São Luiz, R. Santo Amaro, 80 - Glória, Rio de Janeiro - RJ, 22211-230, Brazil.
Background: The congenital absence of the left atrial appendage (LAA) is an extremely rare anatomical anomaly, with only 23 cases documented in medical literature. The LAA plays a critical role in thrombus formation, particularly in patients with atrial fibrillation (AF), thus impacting stroke prevention strategies and the management of anticoagulation.
Case Summary: We report a 48-year-old male with a 2-year history of hypertension and prior episodes of tachycardic palpitations, who presented with AF and chest pain.
Eur Stroke J
December 2024
Neurology Department, Hôpital Fondation A. de Rothschild, Paris, France.
Background: Collateral circulation plays a key role in acute ischemic stroke. We sought to determine the association between the arterial collateral status, estimated by the Hypoperfusion Intensity Ratio (HIR) on perfusion MRI, and stroke etiology in anterior circulation large vessel occlusion (LVO).
Methods: We retrospectively analyzed anterior circulation LVO acute stroke patients with a baseline perfusion MRI performed within 24 h from symptom onset.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!