There is an unmet clinical need for a spinal fusion implant material that recapitulates the biological and mechanical performance of natural bone. We have developed a bioceramic, Sr-HT-Gahnite, which has been identified as a potential fusion device material. This material has the capacity to transform the future of the global interbody devices market, with follow on social, economic, and environmental benefits, rooted in its remarkable combination of mechanical properties and bioactivity. In this study, and in line with FDA requirements, the in vivo preclinical systemic biological safety of a Sr-HT-Gahnite interbody fusion device is assessed over 26 weeks in sheep under good laboratory practice (GLP). Following the in-life phase, animals are assessed for systemic biological effects via blood haematology and clinical biochemistry, strontium dosage analysis in the blood and wool, and histopathology examination of the distant organs including adrenals, brain, heart, kidneys, liver, lungs and bronchi, skeletal muscle, spinal nerves close to the implanted sites, ovaries, and draining lymph nodes. Our results show that no major changes in blood haematology or biochemistry parameters are observed, no systemic distribution of strontium to the blood and wool, and no macroscopic or histopathological abnormalities in the distant organs when Sr-HT-Gahnite was implanted, compared to baseline and control values. Together, these results indicate the systemic safety of the Sr-HT-Gahnite interbody fusion device. The results of this study extend to the systemic safety of other Sr-HT-Gahnite implanted medical devices in contact with bone or tissue, of similar size and manufactured using the described processes. STATEMENT OF SIGNIFICANCE: This paper is considered original and innovative as it is the first that thoroughly reports the systemic biological safety of previously undescribed bioceramic material, Sr-HT-Gahnite. The study has been performed under good laboratory practice, in line with FDA requirements for assessment of a new interbody fusion device, making the results broadly applicable to the translation of sheep models to the human cervical spine; and also the translation of Sr-HT-Gahnite as a biomaterial for use in additional applications. We expect this study to be of broad interest to the readership of Acta Biomaterilia. Its findings are directly applicable to researchers and clinicians working in bone repair and the development of synthetic biomaterials.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2022.01.035DOI Listing

Publication Analysis

Top Keywords

fusion device
16
good laboratory
12
laboratory practice
12
systemic biological
12
safety sr-ht-gahnite
12
interbody fusion
12
sr-ht-gahnite
8
fda requirements
8
biological safety
8
sr-ht-gahnite interbody
8

Similar Publications

Transoral resection of a symptomatic odontoid process aneurysmal bone cyst: illustrative case.

J Neurosurg Case Lessons

January 2025

Departments of Neurosurgery, NYU Langone Health, New York, New York.

Background: Aneurysmal bone cysts (ABCs) are slow-growing, expansile bone tumors most often observed in the long bones and lumbar and thoracic spine. Anterior column ABCs of the spine are rare, and few cases have described their surgical management, particularly for lesions with extension into the odontoid process and the bilateral C2 pedicles. In the present case, the authors describe a two-stage strategy for resection of a symptomatic 2.

View Article and Find Full Text PDF

Paraspinal hematomas are common complications following spine surgery. In general, these hematomas are asymptomatic and resolve without issue. Unfortunately, there is a paucity of literature that describes the recurrence of these hematomas in a chronic setting.

View Article and Find Full Text PDF

3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.

Eur Heart J Case Rep

January 2025

AL Qassimi Hospital, Emirates Health Services (EHS), Wasit Street-Al khazamiya, Sharjah 3500, United Arab Emirates.

Background: The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.

Case Summary: A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block.

View Article and Find Full Text PDF

Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.

Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.

View Article and Find Full Text PDF

Background Context: Correcting sagittal malalignment in adult spinal deformity (ASD) is a challenging task, often requiring complex surgical interventions like pedicle subtraction osteotomies (PSOs). Different types of three-column osteotomies (3COs), including Schwab 3, Schwab 4, Schwab 4 with interbody cages, and the "sandwich" technique, aim to optimize alignment and fusion outcomes. The role of interbody cages in enhancing fusion and segmental correction remains unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!