It has been suggested that maintaining low mean arterial pressure (MAP) in left ventricular assist device (LVAD) recipients is associated with a reduced risk of stroke/death. However, the lower limit of the optimal MAP range has not been established. We aimed to identify this lower limit in a contemporary cohort of LVAD recipients with frequent longitudinal MAP measurements. We analyzed 86,651 MAP measurements in 309 patients with an LVAD (32% LVADs with full magnetic levitation of the impeller) at a tertiary medical center during a mean follow-up of 1.7 ± 1.1 years. Cox proportional hazards regression modeling was used to study the association of serial MAP measurements with stroke/death within 3 years after index discharge. Multivariate analysis identified MAP ≤75 mm Hg, compared with MAP >75 mm Hg, as the low MAP threshold associated with increased risk of death (hazard ratio [HR] 4.74, 95% confidence interval [CI] 2.85 to 7.87, p <0.001), stroke (HR 2.72;, 95% CI 1.39 to 5.33, p = 0.01), and stroke/death (HR 4.45, 95% CI 2.83 to 6.99, p <0.001). The risk associated with MAP ≤75 mm Hg was consistent in subgroups categorized by age, gender, race, device type, renal function, right-sided heart failure, and blood pressure medications. In conclusion, our findings suggest that maintaining MAP ≤75 mm Hg during long-term follow-up in LVAD recipients is associated with increased risk of stroke/death regardless of risk factors or medical management.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2021.12.045 | DOI Listing |
J Chem Phys
January 2025
Department of Chemistry, Faculty of Science, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
We present velocity-map imaging (VMI) of photoelectrons detached from anions using an optical parametric amplifier operating at a repetition rate as high as 100 kHz. The light source generates femtosecond (fs) laser pulses tunable from near-infrared to ultraviolet (310-2600 nm), which interact synchronously with mass-selected anion bunches. We demonstrate this technique by measuring two-dimensional projections of photoelectrons ejected from silver trimer anions, Ag3-, across a photon energy range from 2.
View Article and Find Full Text PDFSci Rep
January 2025
Key Laboratory of Instrumentation Science, Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, 030051, Shanxi, China.
This paper propose a significantly enhanced YOLOv8 model specifically designed for detecting tongue fissures and teeth marks in Traditional Chinese Medicine (TCM) diagnostic images. By integrating the C2f_DCNv3 module, which incorporates Deformable Convolutions (DCN), replace the original C2f module, enabling the model to exhibit exceptional adaptability to intricate and irregular features, such as fine fissures and teeth marks. Furthermore, the introduction of the Squeeze-and-Excitation (SE) attention mechanism optimizes feature weighting, allowing the model to focus more accurately on key regions of the image, even in the presence of complex backgrounds.
View Article and Find Full Text PDFNat Rev Genet
January 2025
Institute of Ecology and Evolution, University of Oregon, Eugene, OR, USA.
Traditionally, differences among individuals have been divided into genetic and environmental causes. However, both types of variation can underlie regulatory changes in gene expression - that is, epigenetic changes - that persist across cell divisions (developmental differentiation) and even across generations (transgenerational inheritance). Increasingly, epigenetic variation among individuals is recognized as an important factor in human diseases and ageing.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Background: Diffusion-weighted (DW) turbo-spin-echo (TSE) imaging offers improved geometric fidelity compared to single-shot echo-planar-imaging (EPI). However, it suffers from low signal-to-noise ratio (SNR) and prolonged acquisition times, thereby restricting its applications in diagnosis and MRI-guided radiotherapy (MRgRT).
Purpose: To develop a joint k-b space reconstruction algorithm for concurrent reconstruction of DW-TSE images and the apparent diffusion coefficient (ADC) map with enhanced image quality and more accurate quantitative measurements.
BMJ Open
January 2025
Department of Rheumatology and Physiotherapy, Third Faculty of Medicine, Charles University and Thomayer University Hospital, Prague, Czech Republic
Introduction: Upper limb (UL) impairment is common in people with multiple sclerosis (pwMS), and functional recovery of the UL is a key rehabilitation goal. Technology-based approaches, like virtual reality (VR), are increasingly promising. While most VR environments are task-oriented, our clinical approach integrates neuroproprioceptive 'facilitation and inhibition' (NFI) principles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!