A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Algorithms for Automated Timed Up-and-Go Test Subtask and Step Frequency Analysis. | LitMetric

AI Article Synopsis

  • Frailty is a significant concern as societies age, prompting the need for tools that can help detect and monitor frailty early on.
  • The "Timed Up-and-Go" test is a widely used method for assessing elderly individuals' functional ability, and researchers have created an ultrasound device to automate this test.
  • Algorithms were developed to detect the different phases of the test and estimate step frequency, showing a mean error of 0.22 to 0.35 seconds for task transitions and 0.15 Hz for step frequency, with plans for further testing with elderly participants.

Article Abstract

Frailty is one of the major problems associated with an aging society. Therefore, frailty assessment tools which support early detection and autonomous monitoring of the frailty status are heavily needed. One of the most used tests for functional assessment of the elderly is the "Timed Up-and-Go" test. In previous projects, we have developed an ultrasound-based device that enables performing the test autonomously. This paper described the development and validation of algorithms for detection of subtasks (stand up, walk, turn around, walk, sit down) and for step frequency estimation from the Timed Up-and-Go signals. The algorithms have been tested with an annotated test set recorded in 8 healthy subjects. The mean error for the developed subtask transition detection algorithms was in between 0.22 and 0.35 s. The mean step frequency error was 0.15 Hz. Future steps will include prospective evaluation of the algorithms with elderly people.

Download full-text PDF

Source
http://dx.doi.org/10.3233/SHTI210935DOI Listing

Publication Analysis

Top Keywords

step frequency
12
timed up-and-go
8
development algorithms
4
algorithms automated
4
automated timed
4
test
4
up-and-go test
4
test subtask
4
subtask step
4
frequency analysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!