Objective: The jugular foramen (JF) is one of the most complex and challenging skull base regions to approach surgically. The extreme medial approach to access the JF provides the approach angle from an anterior direction and does not require dissection and sacrifice of the jugular bulb (JB) to reach the pars nervosa. The authors compared the Fisch type A approach to the extreme medial approach to access the JF and evaluated the usefulness of the extreme medial approach.

Methods: This study was performed at the Anatomical Laboratory for Visuospatial Innovations in Otolaryngology and Neurosurgery of The Ohio State University. For the comparison of surgical maneuverability and visualization, two angles were measured: 1) the angle of attack (AoA), defined as the widest angle of movement achieved with a straight dissector; and 2) the angle of endoscopic exposure (AoEE), defined as the widest angle of movement in the nasal cavity. The differences in eustachian tube (ET) management, approach angle, surgical maneuverability, and surgical application of the Fisch type A approach to the extreme medial approach were compared.

Results: There was no difference between ET mobilization and transection regarding cranial-caudal (CC) or medial-lateral (ML) AoA (p = 0.646). The CC-AoA of the Fisch type A approach was significantly wider than the CC-AoA of the extreme medial approach (p = 0.001), and the CC-AoEE was significantly wider than the CC-AoA of the extreme medial approach (p < 0.001). There was no significant difference between the CC-AoA of the Fisch type A approach and the CC-AoEE. The ML-AoA of the Fisch type A approach was significantly wider than the ML-AoA of the extreme medial approach (p = 0.033), and the ML-AoEE was significantly wider than ML-AoA in the extreme medial approach (p < 0.001). The ML-AoEE was significantly wider than the ML-AoA in the Fisch type A approach (p = 0.033).

Conclusions: The surgical maneuverability of the extreme medial approach was not inferior to that of the Fisch type A approach. The extreme medial approach can provide excellent surgical field visualization, while preserving the JB. Select cases of chordomas, chondrosarcomas, and JF schwannomas should be considered for an extreme medial approach. These two approaches are complementary, and a case-by-case detailed analysis should be conducted to decide the best approach.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2021.11.JNS212065DOI Listing

Publication Analysis

Top Keywords

extreme medial
44
medial approach
40
fisch type
32
type approach
28
approach
21
approach extreme
12
surgical maneuverability
12
approach 0001
12
wider ml-aoa
12
extreme
11

Similar Publications

Objective: To discuss the elbow skin fold extension line in Kirschner wire internal fixation of extended supracondylar humeral fractures in children.

Methods: The clinical data of 58 children with extended supracondylar fractures of the humerus who met the selection criteria between August 2021 and July 2024 were retrospectively analyzed. In 28 cases, needle placement of medial epicondyle of humerus was performed with the assistance of the elbow skin fold extension line (study group), and 30 cases were assisted by routine touch of the medial epicondyle of the humerus (control group).

View Article and Find Full Text PDF

LMSST-GCN: Longitudinal MRI sub-structural texture guided graph convolution network for improved progression prediction of knee osteoarthritis.

Comput Methods Programs Biomed

January 2025

School of Biomedical Engineering and Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, 1023 Shatai Road, Guangzhou 510515, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, 1023 Shatai Road, Guangzhou 510515, China; Pazhou Lab, Guangzhou 510330, China. Electronic address:

Background And Objectives: Accurate prediction of progression in knee osteoarthritis (KOA) is significant for early personalized intervention. Previous methods commonly focused on quantifying features from a specific sub-structure imaged at baseline and resulted in limited performance. We proposed a longitudinal MRI sub-structural texture-guided graph convolution network (LMSST-GCN) for improved KOA progression prediction.

View Article and Find Full Text PDF

With the remarkable advances in diagnostic ultrasound equipment, there is a growing need for ultrasound diagnosis of muscle and soft tissue injuries in sports injuries. Among these, hamstring strains are often difficult to treat and require early and accurate diagnosis. Injuries to the proximal part of the hamstring often take a long time to heal.

View Article and Find Full Text PDF

Introduction: Rhabdomyosarcoma (RMS) is a common pediatric orbital malignancy but is extremely rare in adults. This study assesses clinical and radiographic features, management, and outcomes in adult orbital RMS patients with comparison to pediatric patients.

Methods: A retrospective chart review from 2000-2023 at Bascom Palmer Eye Institute was conducted evaluating patients aged 0 to 100-years-old with biopsy-confirmed orbital RMS.

View Article and Find Full Text PDF

Minimizing Unnecessary Harvesting of an Extremely Thin Gracilis Tendon During ACL Reconstruction by Referencing the Diameter of the Doubled Semitendinosus Tendon Alone.

Orthop J Sports Med

January 2025

Department of Orthopaedics & Traumatology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR.

Background: The incidence of anterior cruciate ligament reconstruction (ACLR) graft failure is inversely related to the diameter of the ACLR graft. When the diameter of a 4-stranded hamstring tendon graft with a doubled semitendinosus and doubled gracilis tendon (ST×2 + G×2) configuration is <8 mm, the gracilis tendon is often thin.

Hypothesis: (1) The diameter of the doubled semitendinosus tendon (ST×2) alone would be able to predict the probability of a 4-stranded ACLR graft having a diameter of ≥8 mm, and (2) there would be a specific cutoff value for the ST×2 diameter such that the addition of a doubled gracilis tendon (G×2) will not result in a 4-stranded graft with a ≥8-mm diameter.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!