The inactivation processes of coliform bacteria (total and fecal) and sulphito-reducing Clostridium bacteria (vegetative species and spores) in water maturation lagoon of a low-cost nature-based wastewater treatment plant using constructed wetlands and through processes of photolysis in a pilot photoreactor have been comparatively studied. The different inactivation mechanisms by photolysis of these bacteria have been studied following the criteria of different statistical and kinetic models. Clostridium disinfection treatments fit models in which two types of bacteria populations coexist, one sensitive (vegetative species) and the other (spores) resistant to the treatment, the sensitive one (94%) with an inactivation rate of k = 0.24 ± 0.07 min and the resistant one (6%) with k = 0.11 ± 0.05 min. Total coliform photolytic disinfection also shows two populations with different physiological state. The time required to reduce the first logarithmic decimal cycle of the different types of bacteria (physiological states) are δ = 4.2 ± 0.9 and δ = 8.3 ± 1.1 min, respectively. For fecal coliform photolytic disinfection, only bacteria population, with k = 1.15 ± 0.19 min, is found. The results obtained confirm the photolytic disinfection processes and maturation lagoon are effective systems for Clostridia bacteria removal after water treatment by nature-based systems. Total removal of coliform bacteria is not achieved by maturation lagoons, but their reduction is significant using low doses of cumulative radiation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9076734 | PMC |
http://dx.doi.org/10.1007/s11356-021-18184-w | DOI Listing |
BMC Microbiol
November 2024
Chemistry of Natural and Microbial Products Department, Pharmaceutical and Drug Industries Research Institute, National Research Centre, 33 El Buhouth St, Dokki, 12622, Giza, Egypt.
Background: Although there are many uses for metal-organic framework (MOF) based nanocomposites, research shows that these materials have received a lot of interest in the field of water treatment, namely in the photodegradation of water contaminants, and disinfection of some pathogenic bacteria and fungi. This is brought on by excessive water pollution, a lack of available water, low-quality drinking water, and the emergence of persistent micro-pollutants in water bodies. Photocatalytic methods may be used to remove most water contaminants, and pathogenic microbes, and MOF is an excellent modifying and supporting material for photocatalytic degradation.
View Article and Find Full Text PDFSci Total Environ
November 2024
School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China; Key Laboratory of Yellow River Water Environment in Gansu Province, Lanzhou Jiaotong University, Lanzhou 730070, China.
The chemical components in the natural aquatic environment have the potential to be involved in phototransformation of microplastics (MPs). Little information is available regarding the mediation effects of artificially introduced chemicals on MP phototransformation, especially those used in aquaculture water that are vulnerable to human interference. Herein, this study investigated the phototransformation process and mechanism of polypropylene microplastic (PP MPs) in presence of trichloroisocyanuric acid (TCCA) disinfectant with unique properties unlike the conventional inorganic chlorine disinfectants.
View Article and Find Full Text PDFWater Res
February 2024
Fujian Key Laboratory of Coastal Pollution Prevention and Control, College of the Environment & Ecology, Xiamen University, Xiamen 361102, China. Electronic address:
Organic micropollutants present in disinfected wastewater and discharged to sunlit surface waters may be transformed by multiple processes, such as chlorination due to the presence of chlorine residuals, solar irradiation as well as solar-irradiated chlorine residues. This study reports, for the first time, the multi-scenario degradation kinetics, transformation products, and risk evolution of calcium channel blockers (CCBs), a class of emerging pharmaceutical contaminants with worldwide prevalence in natural waters and wastewater. It was found that the chlorination of the studied CCBs (amlodipine (AML) and verapamil (VER)) was dominated by the reaction of HOCl with their neutral species, with second-order rate constants of 6.
View Article and Find Full Text PDFACS ES T Water
November 2023
Centre for Water Resources Studies. Department of Civil & Resource Engineering, Dalhousie University, Halifax B3H 4R2, NS, Canada.
This study assesses the efficacy of ultraviolet light-emitting diodes (UV LEDs) for deactivating (pure culture) and (pure culture and biofilms) on relevant drinking water distribution system surfaces (cast iron and stainless steel). UV LED treatment at 280 nm demonstrated superior performance compared to that at 365 nm, achieving a 4.8 log reduction value (LRV) for pure cultures and, for biofilms, 4.
View Article and Find Full Text PDFWater Sci Technol
April 2023
Radiation Chemistry Department, Institute for Energy Security and Environmental Safety, Centre for Energy Research, H-1121, Konkoly-Thege Miklós út 29-33, Budapest, Hungary E-mail:
ClO plays a key role in the UV/chlorine process besides Cl, Cl2 - , and OH. In many experiments, ClO proved to be the main reactant that destroyed the organic pollutants in advanced oxidation process. About 200 rate constants of ClO reactions were collected from the literature, grouped together according to the chemical structure, and the molecular structure dependencies were evaluated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!