In Fontan patients, any pulmonary stenosis may impede free passive inflow into the pulmonary circuit and elevate central venous pressure. When stenting such pulmonary stenosis, dislocation of a stent is a feared complication. Here, we report on a successful retrieval of a dislocated Cook Formula stent into the peripheral left pulmonary artery in a Fontan patient with protein-losing enteropathy using a steerable sheath and a grasping forceps. Furthermore, a successful stent implantation for treating the stenosis was possible. Subsequently, we simulated the retraction technique ex vivo. To manage stent dislocation during complex pediatric catheter interventions, we can recommend the use of a steerable sheath guiding a grasping forceps. A dislocated stent can be grasped, completely longitudinally refolded, and safely retrieved.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8763580PMC
http://dx.doi.org/10.1055/s-0041-1736207DOI Listing

Publication Analysis

Top Keywords

grasping forceps
12
steerable sheath
12
retrieval dislocated
8
dislocated stent
8
fontan patient
8
pulmonary stenosis
8
stent
6
stent grasping
4
forceps steerable
4
sheath fontan
4

Similar Publications

Introduction and aim Laparoscopic surgery has revolutionized the field of surgery over the past few decades. The learning curve in laparoscopy is known to be slow, flat, and complex. This study aims to conduct a comparative analysis of laparoscopic skills, specifically focusing on suturing, knot tying, and needle handling, between novices and experts.

View Article and Find Full Text PDF

DMEK Surgical Strategy in Aphakic and Vitrectomized Eyes.

Eur J Ophthalmol

January 2025

Cornea and Refractive Surgery Unit, Instituto de Microcirugía Ocular (IMO), Barcelona, 08035, Spain.

Article Synopsis
  • After 15 years of DMEK experience, the technique has shown high success rates but still struggles with certain eye conditions like aphakia and eyes that have had vitrectomy.
  • A new method involves injecting an air bubble under the Descemet membrane graft to help unroll it more efficiently during surgery.
  • This approach has been found to decrease surgical time while ensuring successful attachment of the graft, offering a promising option for complex DMEK cases.
View Article and Find Full Text PDF

Introduction: Hand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar® hydraulic dynamometer (JD), the gold standard.

Methods: Fifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD.

View Article and Find Full Text PDF

Migrated intra-uterine device to infra-umbilical skin: a rare case report.

BMC Womens Health

December 2024

Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.

Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.

View Article and Find Full Text PDF

Utilizing the Ellik bladder evacuator during cystoscopic retrieval of urocystoliths in 12 dogs.

J Vet Intern Med

December 2024

North Carolina Veterinary Hospital, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, USA.

Background: Urocystolithiasis is a common problem in dogs; many canine uroliths are resistant to medical dissolution. Novel management options would expand, and in some cases improve, current urolith retrieval strategies.

Hypothesis/objectives: To describe a previously unreported technique by the Ellik bladder evacuator (EE) to assist in minimally invasive, cystoscopic retrieval of canine cystoliths.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!