Ultrahigh-frequency ultrasound (UHFUS) allows sharp visualization of human small muscular arteries. This may help in elucidating some aspects of the pathophysiology of arterial aging, such as the stiffness gradient between large and small conduit arteries and its consequences on the microcirculation, as well as vascular diseases affecting medium-sized arteries. However, UHFUS use is still limited, partly because of the lack of validated tools to quantify vascular structure and mechanical properties of small muscular arteries. In this validation study, scans of digital arteries were obtained with UHFUS (VevoMD, Visualsonics-Fujifilm, Toronto, ON, Canada), analyzed using Carotid Studio software (Quipu, Pisa, Italy) and compared with the manual measurement. Agreement between the two techniques on measures of diameter, distension and intima-media thickness (IMT) was evaluated using Bland-Altman analyses; inter- and intra-operator reproducibility was evaluated using coefficients of variation (CVs). Overall, no trend or significant bias was observed between Carotid Studio and manual analysis. All limits of agreement were acceptable. The intra-observer CV of diastolic diameter and IMT were 4.1% and 4.2%, respectively. The inter-observer CV for diastolic diameter and IMT were 7.3% and 5.4%, respectively. Intra- and inter-observer CVs for distension were higher (25.7% and 26.7%, respectively). These results suggest that the Carotid Studio software is a valid and reproducible tool to study UHFUS scans of digital arteries, with potential utility both in rare vascular diseases of medium-sized arteries and in the study of the pathophysiology of arterial aging in general.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2021.12.008DOI Listing

Publication Analysis

Top Keywords

digital arteries
12
carotid studio
12
vascular structure
8
structure mechanical
8
mechanical properties
8
arteries
8
ultrahigh-frequency ultrasound
8
small muscular
8
muscular arteries
8
pathophysiology arterial
8

Similar Publications

Implementation Strategies and Ergonomic Factors in Robot-assisted Microsurgery.

J Robot Surg

January 2025

BG Trauma Center Ludwigshafen, Department for Plastic, Hand and Reconstructive Surgery, Department of Plastic Surgery for the Heidelberg University, Ludwig-Guttmann-Straße 13, 67071, Ludwigshafen, Germany.

Robot-assisted surgery represents a significant innovation in reconstructive microsurgery, providing enhanced precision and reduced surgeon fatigue. This study examines the integration of robotic assistance in a series of 85 consecutive robot-assisted microsurgical (RAMS) operations. It aims to evaluate changes in the integration of RAMS during the implementation phase in a single institution.

View Article and Find Full Text PDF

Clinical Manifestations.

Alzheimers Dement

December 2024

Sanatorio de la Trinidad Mitre, Buenos Aires, Argentina.

Background: Dural arteriovenous fistulas (DAVFs) are abnormal communications between dural arteries and cortical, meningeal, or dural sinus veins. They represent 10-15% of intracranial arteriovenous malformations. In rare cases, they have been associated with potentially reversible cognitive impairment and dementia.

View Article and Find Full Text PDF

The popliteal artery segment is particularly challenging for endovascular treatment. Stents used for treating popliteal artery lesions are usually associated with an increased risk of stent fracture and re-occlusion. The Supera stent is designed to withstand mechanical stress, with a low risk of fracture.

View Article and Find Full Text PDF

Introduction: Renal artery pseudoaneurysm is a rare yet serious complication following percutaneous nephrolithotomy, especially in patients with solitary kidneys. Effective management is crucial to prevent further renal damage.

Case Presentation: We report a case of a 41-year-old male with a solitary kidney who experienced gross hematuria and renal insufficiency 3 months after percutaneous nephrolithotomy.

View Article and Find Full Text PDF

Measurements on slope parameter mapping based on dual-energy CT enterography for improving Crohn's disease diagnosis and inflammatory activity evaluation.

Sci Rep

January 2025

Department of Radiology, Zhongshan Hospital Affiliated to Xiamen University, School of Medicine, Xiamen University, No.201-209 Hubinnan Road, Siming District, Xiamen, 361004, Fujian Province, China.

Article Synopsis
  • The study evaluates the effectiveness of slope parameter images (SPI) from dual-phase dual-energy CT enterography (DE-CTE) for diagnosing and assessing Crohn's disease (CD) activity.
  • Researchers analyzed data from 76 CD patients and 53 controls, finding significant differences in dual-phase SP and HU values between groups, indicating higher values in affected individuals.
  • The findings suggest that the AP SP of mesenteric fat shows the highest diagnostic potential for CD, emphasizing the usefulness of SPI in both diagnosis and assessing inflammation levels.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?