The purpose of the present study was to experimentally assess the synergistic effects of wear and corrosion on NiTi alloy in comparison with Ti-6Al-4V alloy, the most extensively used titanium alloy in biomedical applications. Both alloys were processed by an additive manufacturing laser beam directed energy deposition (LB-DED) technique, namely laser engineered net shaping (LENS), and analyzed via tribocorrosion tests by using the ball-on-plate configuration. The tests were carried out in phosphate buffered saline solution at 37 °C under open circuit potential (OCP) to simulate the body environment and temperature. The synergistic effect of wear and corrosion was found to result in an improved wear resistance in both materials. It was also observed that, for the process parameters used, the LB-DED NiTi alloy exhibits a lower tendency to corrosion as compared to the LB-DED Ti-6Al-4V alloy. It is expected that, during the service life as an implant, the NiTi alloy is less susceptible to the metallic ions release when compared with the Ti-6Al-4V alloy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780431 | PMC |
http://dx.doi.org/10.3390/ma15020691 | DOI Listing |
Int J Dent
December 2024
College of Dentistry, King Saud University, P. O. Box 68004, Riyadh 11527, Saudi Arabia.
XP-endo files are composed of Max-Wire alloy, which was developed by FKG Dentaire (La Chaux-de-Fonds, Switzerland). This alloy, known as Martensite-Austenite Electropolish Flex, is the first NiTi alloy used in endodontics to combine the shape memory effect with superelasticity for use in clinical practice. This article aims to provide a comprehensive overview of the existing knowledge and evidence regarding different XP-endo files and systems, XP-endo Finisher (XPEF), XP-endo Shaper (XPES), XP-endo Retreatment (XPER), XP-endo Rise (XPE-Rise), and XPE-Rise Retreatment (XPE-Rise-R), to help clinicians understand their different properties and recommended clinical uses.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China.
In the Ni-Ti shape memory alloy system, Cu elements are used to replace Ni elements. A NiTiCu alloy with a molar ratio of 45:50:5 was prepared using laser selective melting technology. The density, composition, microstructure, and mechanical properties of the NiTiCu alloy were investigated.
View Article and Find Full Text PDFPolymers (Basel)
November 2024
School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China.
Mechanocaloric cooling/heat pumping with zero carbon emission and high efficiency shows great potential for replacing traditional refrigeration with vapor compression. Mechanocaloric prototypes that are developed using shape memory alloys (SMAs) face the problems of a large driving force and high cost. In this work, we report a low-crystalline thermoplastic polyetherurethane (TPU) elastomer fiber with a low actuation force and good mechanocaloric performance.
View Article and Find Full Text PDFMolecules
November 2024
BT Orthodontic Office "Galeria Uśmiechów", Polskie Towarzystwo Techniki Ortodontycznej, Plac Piłsudskiego 25, 51-152 Wroclaw, Poland.
This study investigates the release of metal ions from commonly used orthodontic archwires, specifically, stainless steel (SS), nickel-titanium (NiTi), chromium-cobalt (CrCo), and titanium-molybdenum (TMA) alloys. To simulate oral conditions, each type of wire was immersed in artificial saliva at body temperature for a four-week period. Ion release levels were analyzed through ICP-OES mass spectrometry.
View Article and Find Full Text PDFBMC Oral Health
December 2024
Faculty of Dentistry, Department of Endodontics, Cukurova University, Adana, 01330, Turkey.
Background: Nickel titanium (NiTi) rotary files have drastically altered the treatment protocol in endodontics, allowing for faster and easier preparation and more thorough irrigation of the root canal system. Despite the advantages of the NiTi files, instrument separation still remains a major concern. The aim of this study was to compare the cyclic fatigue resistance of three different single-file NiTi systems after clinical use: WaveOne Gold (WOG, Dentsply Maillefer, Ballaigues, Switzerland), One Curve (OC, Micro Mega, Besancon, France), and Reciproc Blue (RPC Blue, VDW, Munich, Germany).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!