The detection of motor developmental problems, especially developmental coordination disorder, at age 5-6 contributes to early interventions. Here, we summarize evidence on (1) criterion validity of screening instruments for motor developmental problems at age 5-6, and (2) their applicability. We systematically searched seven databases for studies assessing criterion validity of these screening instruments using the M-ABC as reference standard. We applied COSMIN criteria for systematic reviews of screening instruments to describe the correlation between the tests and the M-ABC. We extracted information on correlation coefficients or area under the receiver operating curve, sensitivity and specificity, and applicability in practice. We included eleven studies, assessing eight instruments: three performance-based tests (MAND, MOT 4-6, BFMT) and five questionnaires (DCD-Q, PQ, ASQ-3, MOQ-T-FI, M-ABC-2-C). The quality of seven studies was fair, one was good, and three were excellent. Seven studies reported low correlation coefficients or AUC (<0.70), four did not report these. Sensitivities ranged from 21-87% and specificities from 50-96%, with the MOT4-6 having the highest sensitivity and specificity. The DCD-Q, PQ, ASQ-3, MOQ-T-FI, and M-ABC-2-C scored highest on applicability. In conclusion, none of the instruments were sufficiently valid for motor screening at age 5-6. More research is needed on screening instruments of motor delay at age 5-6.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8775360 | PMC |
http://dx.doi.org/10.3390/ijerph19020781 | DOI Listing |
Anal Chem
January 2025
The Jiangxi Province Key Laboratory for Diagnosis, Treatment, and Rehabilitation of cancer in Chinese Medicine, Jiangxi University of Chinese Medicine, Nanchang 330004, P. R. China.
An online reactive internal extraction electrospray ionization (iEESI) method was developed for the rapid determination of organic and inorganic speciation information for selenium in poultry tissue samples without complex sample pretreatment. The addition of citric acid as a reducing agent to the internal extraction solvent of methanol/acetic acid (99:1, V/V) for iEESI resulted in the reduction of selenate in the sample to selenite, accompanied by the production of malic acid as an oxidation product. The quantitative analysis of selenate was conducted by using malic acid.
View Article and Find Full Text PDFTurk Kardiyol Dern Ars
January 2025
Department of Cardiology, University of Health Sciences, Derince Training and Research Hospital, Kocaeli, Türkiye.
Cardiac implantable electronic device (CIED) implantation is a diagnostic and therapeutic method that is being employed on a growing number of patients globally. These devices require long-term follow-up and monitoring, and after implantation, regular follow-ups are conducted at specific intervals. These follow-ups provide crucial information about both the device and the patient, aiding in diagnosis and guiding treatment.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC 3800, Australia.
Conventional endoscopy is limited in its ability to examine the small bowel and perform long-term monitoring due to the risk of infection and tissue perforation. Wireless Capsule Endoscopy (WCE) is a painless and non-invasive method of examining the body's internal organs using a small camera that is swallowed like a pill. The existing active locomotion technologies do not have a practical localization system to control the capsule's movement within the body.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Ophthalmic Instrumentation Development Lab, The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Wilmer 233, 600 N. Wolfe St., Baltimore, MD 21287, USA.
Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Biomedicine Research Center of Strasbourg (CRBS), UR 3072, "Mitochondria, Oxidative Stress and Muscle Plasticity", Faculty of Medicine, University of Strasbourg, 67000 Strasbourg, France.
The continuous monitoring of oxygen saturation (SpO) and respiratory rates (RRs) are major clinical issues in many cardio-respiratory diseases and have been of tremendous importance during the COVID-19 pandemic. The early detection of hypoxemia was crucial since it precedes significant complications, and SpO follow-up allowed early hospital discharge in patients needing oxygen therapy. Nevertheless, fingertip devices showed some practical limitations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!