Introduction: Endometriosis surgery is associated with a high risk of reoperation due to an insufficient recognition of endometriotic lesions. Our aim was to explore the role of near-infrared fluorescence (NIRF) imaging for the visualization and identification of endometriotic lesions next to conventional white light (WL) laparoscopy.

Materials And Methods: Fifteen women scheduled for diagnostic laparoscopy in whom peritoneal endometriosis was suspected were included. Peritoneal exploration was performed in WL, followed by NIRF imaging after ICG administration. Biopsies of all the suspected lesions were taken for histological examination. Subjective evaluations of the equipment and NIRF imaging were also performed.

Results: Only 61% (44) of the biopsied lesions contained endometriosis. The positive predictive value (PPV) for the lesions found in WL was 64%. The PPV for the lesions found under NIRF was 69% and the PPV for the lesions found in both modes was 61%. The mean satisfaction of surgeons regarding the surgical procedure and equipment using both imaging modalities was 6.5 ( > 0.05) on a 10 item Likert scale and the mean satisfaction with the quality of the NIRF imaging was 7.4 ( > 0.05).

Conclusion: In this study, the additional value of NIRF imaging, although feasible, was found to be limited for the intraoperative detection of endometriotic lesions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8779744PMC
http://dx.doi.org/10.3390/life12010015DOI Listing

Publication Analysis

Top Keywords

nirf imaging
20
endometriotic lesions
12
ppv lesions
12
near-infrared fluorescence
8
intraoperative detection
8
lesions
8
imaging
7
nirf
6
fluorescence imaging
4
imaging intraoperative
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!