Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Prolonged mechanical ventilation in preterm infants may cause complications. We aimed to analyze the variables affecting extubation outcomes in preterm infants at high risk of extubation failure.
Methods: This was a single-center, observational, retrospective study. Extubation failure was defined as survival with the need for reintubation within 72 h. Successfully extubated neonates (group 1) were compared to those with failed extubation (group 2). Multivariate logistic regression analysis evaluated factors that predicted extubation outcomes.
Results: Eighty infants with a birth weight under 1000 g and/or gestational age (GA) under 28 weeks were included. Extubation failure occurred in 29 (36.2%) and success in 51 (63.8%) neonates. Most failures (75.9%) occurred within 24 h. Pre-extubation inspired oxygen fraction (FiO) of 27% had a sensitivity of 58.6% and specificity of 64.7% for extubation failure. Post-extubation FiO of 32% had a sensitivity of 65.5% and specificity of 62.8% for failure. Prolonged membrane rupture (PROM) and high GA were associated with extubation success in multivariate logistic regression analysis.
Conclusions: High GA and PROM were associated with extubation success. Pre- and post-extubation FiO values were not significantly predictive of extubation failure. Further studies should evaluate if overall assessment, including ventilatory parameters and clinical factors, can predict extubation success in neonates.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8774464 | PMC |
http://dx.doi.org/10.3390/children9010030 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!