Small, triaxial force plate.

Med Biol Eng Comput

Published: November 1987

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02447343DOI Listing

Publication Analysis

Top Keywords

small triaxial
4
triaxial force
4
force plate
4
small
1
force
1
plate
1

Similar Publications

Highly Sensitive Linear Triaxial Force Sensor Based on Multimodal Sensing for 3D Pose Reconstruction.

Small Methods

January 2025

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China.

Flexible sensing offers real-time force monitoring, presenting a versatile and effective solution for dexterous manipulation, healthcare, environmental exploration, and perception of physical properties. Nonetheless, a limitation of many existing flexible force sensors stems from their isotropic structure or material properties, preventing them from simultaneously detecting both the direction and magnitude of the applied force. Herein, a high-performance 3D force sensor based on orthogonal multimodal sensing, the cancellation principle, and the strain effect is proposed.

View Article and Find Full Text PDF

Possible differences in the performances of vibration-reducing gloves when used with hammers of different sizes.

Heliyon

November 2024

DIIEM, Department of Industrial, Electronical and Mechanical Engineering, University of Roma Tre, via Vito Volterra, 62, 00146, Rome, Italy.

Protection provided by vibration-reducing gloves (VR) when used with impact tools can be considerably different from that measured following the ISO 10819 Standard. This paper investigates the transmissibility, at the palm level, of three different types of vibration-reducing gloves (air bubbles; gel; neoprene) and a working leather glove, while using 8 different models of electro-pneumatic hammers for chiseling rock in a limestone quarry plant. The capability to reduce the triaxial vibration as the average of all the tested hammers results limited: 12 % for both the gloves in gel and neoprene, and 7 % for the glove in air.

View Article and Find Full Text PDF

Applicability of Small and Low-Cost Magnetic Sensors to Geophysical Exploration.

Sensors (Basel)

October 2024

Department of Earth, Environmental and Resources Sciences, University of Naples "Federico II", 80126 Naples, Italy.

In the past few decades, there has been a notable technological advancement in geophysical sensors. In the case of magnetometry, several sensors were used, having the common feature of being miniaturized and lightweight, thus idoneous to be carried by UAVs in drone-borne magnetometric surveys. A common feature is that their sensitivity ranges from 0.

View Article and Find Full Text PDF

In order to master the strength and deformation characteristics, including the macro-micro failure mechanism of soft rock samples with penetrating joints under triaxial loading, a series of numerical triaxial tests have been carried out. The strength and deformation characteristics, failure modes, crack propagation, distribution of force chains, and the influences of joint dip angles and confining pressures have been analyzed and compared with the laboratory test results. The results show that (1) the residual strength ratio of jointed rock samples generally increases first and then decreases with the increase in joint dip angles under the same confining pressure and reaches the maximum value around 23-24°.

View Article and Find Full Text PDF

The Detection of Physiological Changes Using a Triaxial Accelerometer and Temperature Sensor-Equipped Bolus-Type Biosensor in Calves.

Animals (Basel)

September 2024

Department of Farm Animal Medicine and Institute of Veterinary Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Republic of Korea.

In this study, a newly developed small wireless bolus biosensor, equipped with a triaxial accelerometer and temperature sensors, was applied to assess physiological changes in calves. The biosensor was orally implanted in calves, and its retention rate and location in the forestomach were examined. Data transmitted at 10 min intervals were analyzed to determine the characteristics of the calves at 10 and 100 days of age.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!