A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction. | LitMetric

AI Article Synopsis

  • A rapid analytical method was developed to assess levels of antibacterial agents, plasticizers, and UV filters in human urine for exposure assessment.
  • The method employs supported liquid extraction (SLE) and isotope-dilution ultraperformance liquid chromatography-tandem mass spectrometry (ID-UPLC-MS/MS) techniques, validating their effectiveness by analyzing 41 urine samples from children and adolescents.
  • Results showed strong recovery rates and precision, confirming the method’s reliability and potential use for human biomonitoring of these chemicals.

Article Abstract

The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens-bisphenols A (BPA) and its analogs, triclosan (TCS), triclocarban, and benzophenone-3 (BP-3)-in human urine. We further measured the levels of these chemicals in children and adolescents. We used a supported liquid extraction (SLE) technique coupled with an isotope-dilution ultraperformance liquid chromatography-tandem mass spectrometry (ID-UPLC-MS/MS) method to assess the detection performance for these chemicals. Forty-one urine samples from 13 children and 28 adolescents were assessed to demonstrate the capability and feasibility of our method. An acceptable recovery (75.6-102.4%) and matrix effect (precision < 14.2%) in the three-level spiked artificial urine samples were achieved, and good performance of the validated ID-UPLC-MS/MS method regarding linearity, limits of detection, and quantitation was achieved. The within-run and between-run accuracy and precision also demonstrated the sensitivity and stability of this analytical method, applied after SLE. We concluded that the ID-UPLC-MS/MS method with SLE pretreatment is a valuable analytical method for the investigation of urinary antibacterial agents, plasticizers, and ultraviolet filters in humans, useful for human biomonitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781104PMC
http://dx.doi.org/10.3390/toxics10010021DOI Listing

Publication Analysis

Top Keywords

analytical method
12
id-uplc-ms/ms method
12
analogs triclosan
8
human urine
8
method
8
supported liquid
8
liquid extraction
8
antibacterial agents
8
agents plasticizers
8
plasticizers ultraviolet
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!