This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt-chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever's length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8774799 | PMC |
http://dx.doi.org/10.3390/dj10010012 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Orthopedic Department, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Background: Adhesion formation poses a significant challenge for both patients and hand surgeons following tendon repair. One common strategy to prevent adhesion formation is the use of physical barriers. This study aimed to compare the outcomes of extensor tendon repair with and without the application of the OrthoWrap bioresorbable Sheet, specifically in terms of adhesion prevention.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
December 2024
Service de Chirurgie Orthopédique et Traumatologique, Hôpital de la Cavale Blanche, Boulevard Tanguy Prigent, Brest 29200, France; Université de Bretagne Occidentale, UBO, Brest 29200, France; LaTIM, INSERM, UMR 1101, SFR IBSAM, Avenue Foch, Brest 29200, France. Electronic address:
Introduction: With the aging population comes an increase in the number of distal radial fractures and therefore in the number of cases requiring volar locking plate (VLP) fixation. The complication rates after VLP fixation vary greatly from one study to the next. Several authors have already focused on these complications and how to lower their rate.
View Article and Find Full Text PDFBreast cancer is the leading cause of death and morbidity among women. A major challenge for clinical management of breast cancer is the dissemination of breast cancer cells from the primary tumor site via lymphatic drainage, resulting in metastatic tumor spread. Recent studies have found that high expression of the microRNA miR-146a-5p is associated with better survival outcomes for breast cancer patients.
View Article and Find Full Text PDFRev Cardiovasc Med
December 2024
Department of Cardiology, University Clinical Center of Serbia, 11000 Belgrade, Serbia.
Background: Elective unprotected left main (ULM) percutaneous coronary intervention (PCI) has long-term mortality rates comparable to surgical revascularization, thanks to advances in drug-eluting stent (DES) design, improved PCI techniques, and frequent use of intravascular imaging. However, urgent PCI of ULM culprit lesions remains associated with high in-hospital mortality and unfavourable long-term outcomes, including DES restenosis and stent thrombosis (ST). This analysis aimed to examine the long-term outcomes and healing of DES implanted in ULM during primary PCI using high-resolution optical coherence tomography (OCT) imaging.
View Article and Find Full Text PDFJ Indian Soc Periodontol
December 2024
Department of Periodontology and Implantology, G. Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India.
Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.
Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!