Steam sterilization of channeled medical devices requires steam penetration into narrow channels. However, a quantitative characterization of this phenomenon in practical situations is lacking. This study evaluates the effect of load, loading pattern, and wrapping system on steam penetration into channels. We tested the hypothesis that a 70 cm tube with one closed end could be representative of the worst case for steam penetration in wrapped channeled instruments in practical conditions. A validated sterilization process was run in a sterilizer equipped with infrared sensors for the measurement of water vapor fraction (WVF). WVF values collected at the closed end of an unwrapped 70 cm reference tube were compared to those obtained at the closed end of wrapped 50 cm test tubes, representative for channeled devices in the clinical practice. The open ends of the test tubes were placed inside packs, testing the effects of different combinations of wrappings, load amounts, and pack positions. The worst case for steam penetration was experimentally defined as the condition showing the lowest WVF value during the exposure phase. WVF values at the closed end of 50 cm long tubes were affected by load amount, wrapping, and pack position. Steam penetration was higher for heavier loads in rigid containers, but lower for heavier loads in soft wrappings (pouch, non-woven fabric, and crepe). In all the tested combinations of load/wrappings related to the clinical practice the 70 cm reference tube displayed lower WVF values than the wrapped 50 cm test tubes, indicating worse steam penetration in the reference than test tubes. Our findings provide experimental evidence that a 70 cm is the worst case in all practical combinations of load and wrapping encountered in the field. The 70 cm tube is a representative for a wrapped 50 cm channel with one end closed and for a wrapped 100 cm channel with both ends open. A measuring system integrating the WVF sensor on a 70 cm tube may provide a physics-based, quantitative steam penetration test for real-time monitoring of the steam sterilization process of channeled instruments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8757681PMC
http://dx.doi.org/10.3389/fmedt.2020.566143DOI Listing

Publication Analysis

Top Keywords

steam penetration
32
test tubes
16
channeled instruments
12
worst case
12
wvf values
12
steam
9
monitoring steam
8
penetration
8
practical situations
8
steam sterilization
8

Similar Publications

Citicoline eluting hydrogels for therapeutic contact lenses intended to treat neurodegenerative diabetic ocular diseases.

Int J Pharm

December 2024

Centro de Química Estrutural (CQE), Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, Lisboa 1049-001, Portugal; Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Caparica, Almada, Portugal.

Ophthalmic neurodegenerative diseases related to diabetes, such as glaucoma and retinopathy, are among the major causes of blindness in the world. Citicoline (CIT) in the form of eye drops is currently used for the treatment/prevention of these diseases, which affect the posterior segment of the eye. To ensure the drug penetration into the back of the eye, frequent instillations of highly concentrated drug solutions are required with potential side effects.

View Article and Find Full Text PDF

A novel green approach for reactive printing of cotton/cellulosic regenerated blended fabrics using trisodium nitrilotriacetate.

Sci Rep

October 2024

Dyeing, Printing and Dye Intermediates Department, Textile Research and Technology Institute, National Research Centre, 33 EL Buhouth St, Dokki, 12622, Giza, Egypt.

Owing to their comfort, handle, and aesthetic characteristics, cotton fabrics will always be the first and primary choice for clothing and apparel. In recent years, regenerated cellulosic fabrics like bamboo, Tencel, and modal fabrics have had many natural advantages. Fabrics based on blending cotton fibres with regenerated cellulosic fibres are considered promising products in textile industry sectors.

View Article and Find Full Text PDF
Article Synopsis
  • Thermal processing is important for the safety of foods, but it can also trigger allergic reactions in some people, impacting their health.
  • Various methods of thermal processing, like boiling and frying, can reduce the allergenic properties of food by changing protein structures, but factors like temperature and time are crucial.
  • There are potential risks with both conventional (like roasting) and novel (like microwave) heating methods, as improper control can either worsen allergenicity or create safety issues.
View Article and Find Full Text PDF

Tailoring the structural and physicochemical properties of rice straw cellulose-based cryogels by cell-mediated polyhydroxyalkanoate deposition.

Carbohydr Polym

December 2024

Interdisciplinary Platform for Sustainable Plastics towards a Circular Economy-Spanish National Research Council (SusPlast), CSIC, Madrid 28006, Spain; Polymer Biotechnology Group, Biological Research Centre Margarita Salas, Spanish National Research Council (CIB), CSIC, C. Ramiro de Maeztu, 9, 28040 Madrid, Spain. Electronic address:

This study presents a novel biotechnological approach for creating water vapor-resistant cryogels with improved integrity. Rice straw cellulose was transformed into nanofibrils through TEMPO-mediated oxidation and high-pressure homogenization. The resulting cryogels remained firm even when immersed in aqueous media, whose pores were used by live cell to deposit polyhydroxyalkanoate (PHA) particles inside them.

View Article and Find Full Text PDF

The increasing penetration of high-volatility renewable energy sources in the power system presents higher demands for flexibility from coal-fired power plant (CFPP). To enhance the flexibility of CFPPs, researchers have conducted a significant amount of thermal-system-level research in recent years on increasing system peak shaving depth. However, the load ramp rate of CFPPs under deep peak shaving is rarely discussed, despite its significance to the overall flexibility performance of CFPPs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!