Minimally invasive procurement of uterine grafts for transplantation can decrease living donor recovery time. We examined recipient outcomes for grafts procured by robotic-assisted donor hysterectomies with transvaginal extraction in the Dallas UtErus Transplant Study (DUETS). All 5 grafts were successfully transplanted. Recipients had a median 4.5-hour surgical time, 0.25 L estimated blood loss, and 4-day hospital stay. Four recipients had grade III surgical complications and three had acute cellular rejection. At 18 months, graft viability was 100%, with an 80% live birth rate. This report demonstrates the feasibility and reproducible success of using uterus grafts from living donors who underwent robotic-assisted donor hysterectomy.