In this investigation, it was assumed that it must be possible to visualize the intrapelvic aspect as accustomed by pelvic surgeons using the anterior intrapelvic (modified Stoppa) approach. Moreover, it was hypothesized, that plate mountings will not only be possible for the symphysis but also at the supra- and infrapectineal aspect as well as to the posterior column. Ten anonymized cadaveric specimens were included in this study. A standard laparoscopic totally extraperitoneal (TEP) approach was used. A total of 10 landmarks were defined that are usually within reach in the open anterior intrapelvic (AIP) approach. Moreover, five different plate mountings were tested. The locations were chosen in accordance with the indication spectrum suitable for open surgery through the traditional AIP approach. It was possible to gain intrapelvic visibility in seven of ten cases. In all of those seven cases, it was technically possible to place plates to the symphysis, superior pubic ramus, as well as longer anterior column plates up to the aspect posterior of the acetabulum. In the last four of the seven cases, it was possible to mount plates to the infrapectineal aspect as well as the posterior column, too. The team, previously trained in arthroscopic surgical techniques as well as pelvic trauma surgery, observed a steep learning curve. This investigation demonstrated, that endoscopic anterior intrapelvic plate osteosynthesis was feasible in the majority of the cases in a series of ten cadaveric models. New instruments will be needed such as extra-long rasp elevators, ball-spikes as well as devices to hold and position plates and extra-long self-holding screwdrivers. With these, endoscopic pelvic surgery will likely be a realistic option for selected pelvic trauma cases in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886590PMC
http://dx.doi.org/10.1007/s00402-022-04346-zDOI Listing

Publication Analysis

Top Keywords

anterior intrapelvic
16
endoscopic anterior
8
intrapelvic plate
8
plate osteosynthesis
8
plate mountings
8
infrapectineal aspect
8
aspect well
8
well posterior
8
posterior column
8
aip approach
8

Similar Publications

Purpose: The primary aim of this study is to determine the rectus abdominis tendon (RAT) insertional anatomy and consequently clarify the extension of secure mobilization of the tendon from the pubic bone in the setting of anterior approaches in pelvic and acetabular reconstruction surgery.

Materials And Methods: Eleven fresh frozen cadaveric pelvises were dissected by two fellowship-trained orthopaedic trauma surgeons utilizing the anterior intrapelvic approach (AIP). The RAT at the pubic body was dissected, and its footprint on the pubic bone was defined, marked, and measured.

View Article and Find Full Text PDF

Introduction: Acetabulum fractures involving both columns are complicated injuries to treat, and achieving satisfactory post operative reduction with less extensile approaches is difficult. These injuries often require dual approaches, associated with their own share of complications. The anterior intrapelvic approach (AIP) addresses both columns through a single approach, minimizing these complications.

View Article and Find Full Text PDF

The intrapelvic approach to the acetabulum.

Arch Orthop Trauma Surg

December 2024

Department of Orthopaedics and Traumatology, Helsinki University Hospital, University of Helsinki, Helsinki, Finland.

The today well accepted intrapelvic approach for acetabular and pelvic ring injury fixation was first described by Hirvensalo and Lindahl in 1993 followed by a more detailed description by Cole and Bolhofner in 1994. Compared to the well-known ilioinguinal approach, described by Letournel, this approach allows an intrapelvic view to the medial acetabulum, while using the ilioinguinal approach a more superior, extrapelvic view, is dissected to the area of the acetabulum. Several names have been used to describe the new intrapelvic approach with increasing usage, mainly ilio-anterior approach, extended Pfannenstiel approach, Stoppa-approach, Rives-Stoppa approach, modified Stoppa approach and recently anterior intrapelvic approach.

View Article and Find Full Text PDF

Background Acetabular fractures with quadrilateral plate involvement have been shown to have a high rate of complications. Anatomic suprapectineal plating systems have been developed to manage these injuries with good short-term outcomes. However, long-term maintenance of anatomical reduction and functional outcomes has yet to be established.

View Article and Find Full Text PDF

Background: Different approaches to the obturator nerve have been described. However, few have focused on the injection point inferior the iliopubic ramus, specifically at the exit of the obturator canal. This study aims to anatomically evaluate the ultrasound-guided obturator nerve block at the exit of the obturator canal, detailing anatomical landmarks and solution distribution.

View Article and Find Full Text PDF