Background: The purpose of this study was to clarify the efficacy of the combination of low-voltage coagulation plus staple line coverage with a polyglycolic acid sheet after bullectomy for primary spontaneous pneumothorax to prevent a postoperative recurrence.

Methods: A total of 143 patients who underwent bullectomy for primary spontaneous pneumothorax between January 2014 and December 2019 were enrolled in this study. We classified the patients into two groups based on additional procedures after bullectomy, namely, low-voltage coagulation for the margin of the staple line plus coverage with a polyglycolic acid sheet (Group A) and staple line coverage with a polyglycolic acid sheet alone (Group B). We evaluated perioperative factors and recurrence-free survival after surgery in the two groups.

Results: Nine patients in Group B developed postoperative recurrences. In contrast, there was no postoperative recurrence in Group A. According to the Kaplan-Meier curves, the 2-year recurrence-free survival rates of the patients were 100% and 90.3%, in Group A and Group B, respectively. The log-rank test showed a significant difference between the two groups ( = 0.031).

Conclusion: Low-voltage coagulation for the margin of a staple line plus coverage with a polyglycolic acid sheet is a useful option as an additional technique after bullectomy for primary spontaneous pneumothorax to prevent a postoperative recurrence.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02184923211072595DOI Listing

Publication Analysis

Top Keywords

coverage polyglycolic
20
polyglycolic acid
20
acid sheet
20
bullectomy primary
16
primary spontaneous
16
spontaneous pneumothorax
16
staple coverage
16
low-voltage coagulation
12
sheet bullectomy
8
pneumothorax prevent
8

Similar Publications

Absorbable biomaterials as adjuvant therapy after thoracoscopy are sometimes used in clinical scenarios. With the prevalence of enhanced rapid recovery in thoracic surgery, drainless video-assisted thoracoscopy surgery (VATS) is often adopted by thoracic surgeons. Here, we discuss utilizing an absorbable biomaterial, Neoveil (Polyglycolic Acid sheet), for drainless VATS to treat early lung cancer.

View Article and Find Full Text PDF

Tracking the effects of PLGA-based nanoparticles on protein expression in living cells through quantitative proteomics.

J Mater Chem B

May 2024

State Key Laboratory of Medical Proteomics, National Chromatographic R. & A. Center, CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.

Mass spectrometry (MS)-based proteomics can identify and quantify the differential abundance of expressed proteins in parallel, and bottom-up proteomic approaches are even approaching comprehensive coverage of the complex eukaryotic proteome. Protein-nanoparticle (NP) interactions have been extensively studied owing to their importance in biological applications and nanotoxicology. However, the proteome-level effects of NPs on cells have received little attention, although changes in protein abundance can reflect the direct effects of nanocarriers on protein expression.

View Article and Find Full Text PDF

Efficacy of mesh coverage in surgical bullectomy for primary spontaneous pneumothorax: A systematic review and meta-analysis.

Surgeon

December 2023

Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Department of Cardiac, Thoracic and Vascular Surgery, National University Heart Centre Singapore, Singapore. Electronic address:

Background And Purpose: Thoracic surgeons are now adopting a new method of using a mesh covering to reduce recurrence in surgical pleurodesis for pneumothorax. We aimed to review the literature and compare the outcomes of using mesh covering as an additional procedure during surgical pleurodesis.

Methods: A comprehensive search was performed from inception to October 2022 on PubMed, Embase, Cochrane and Scopus.

View Article and Find Full Text PDF

Oxidized Regenerated Cellulose versus Polyglycolic Acid for Pleural Coverage in Pneumothorax Surgery.

J Clin Med

May 2023

Department of Thoracic and Cardiovascular Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University College of Medicine, Seoul 03181, Republic of Korea.

Although surgical intervention for spontaneous pneumothorax (SP) reduces the recurrence rate, thoracoscopic surgery is associated with greater postoperative recurrence rates than open thoracotomy. A polyglycolic acid (PGA) sheet or oxidized regenerated cellulose (ORC) mesh can therefore be used for additional coverage after thoracoscopic surgery, and this study compared the clinical impacts of these two materials. From 2018 to 2020, 262 thoracoscopic surgeries for primary SP were performed, of which 125 patients were enrolled in this study, and 48 and 77 patients received ORC and PGA coverage, respectively.

View Article and Find Full Text PDF
Article Synopsis
  • Polyglycolic acid (PGA) sheets are used with fibrin glue in oral and pharyngeal surgeries to cover mucosal defects, but issues with sheet falling off have led to recommendations for prolonged fasting during recovery.
  • A study analyzing 137 patients found that Neoveil Nano® PGA sheets significantly improved engraftment rates compared to Neoveil®, with a 76% overall engraftment rate.
  • The research concluded that fasting duration does not impact engraftment success, suggesting that patients can safely resume oral intake earlier than previously advised.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!