A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In Vivo Comparison of Micro-Balloon Interventions (MBI) Advantage: A Retrospective Cohort Study of DEB-TACE Versus b-TACE and of SIRT Versus b-SIRT. | LitMetric

Purpose: The purpose of this study was to evaluate in vivo the role of the micro-balloon by comparing trans-arterial chemoembolization (DEB-TACE) and selective internal radiotherapy (SIRT) procedures performed with and without balloon micro-catheter (b-DEB-TACE and DEB-TACE/SIRT and b-SIRT) for the treatment of hepatocellular carcinoma (HCC).

Methods: The impact of a balloon micro-catheter on trans-arterial loco-regional treatment was analyzed using non-enhanced post-procedural cone-beam CT (Ne-CBCT) by comparing the attenuation values in the embolized area and the surrounding liver tissue before and after DEB-TACE versus b-DEB-TACE and by comparing 2D/3D dosimetry in single-photon emission computed tomography after SIRT versus b-SIRT, and by comparing the histological count of the beads following orthotopic liver transplantation in the DEB-TACE versus b-DEB-TACE subgroup.

Results: We treated 84 HCC patients using trans-arterial loco-regional therapy. Fifty-three patients (26 DEB-TACE and 27 b-DEB-TACE) were analyzed in the TACE group. Contrast, signal-to-noise ratio, and contrast-to-noise ratio were all significantly higher in b-DEB-TACE subgroup than DEB-TACE (182.33 HU [CI95% 160.3-273.5] vs. 124 HU [CI95% 80.6-163.6]; 8.3 [CI95% 5.7-10.1] vs. 4.5 [CI95% 3.7-6.0]; 6.9 [CI95% 4.3-7.8] vs. 3.1 [CI95% 2.2-5.0] p < 0.05). Thirty-one patients (24 SIRT and 7 b-SIRT) were analyzed in the SIRT group. 2D dosimetry profile evaluation showed an activity intensity peak significantly higher in the b-SIRT than in the SIRT subgroup (987.5 ± 393.8 vs. 567.7 ± 302.2, p = 0.005). Regarding 3D dose analysis, the mean dose administered to the treated lesions was significantly higher in the b-SIRT than in the SIRT group (151.6 Gy ± 53.2 vs. 100.1 Gy ± 43.4, p = 0.01). In histological explanted liver analysis, there was a trend for higher intra-tumoral localization of embolic microspheres for b-DEB-TACE in comparison with DEB-TACE.

Conclusions: Due to the use of three different methods, the results of this study demonstrate in vivo, a better embolization profile of oncological intra-arterial interventions performed with balloon micro-catheter regardless of the embolic agent employed.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-021-03035-5DOI Listing

Publication Analysis

Top Keywords

deb-tace versus
12
sirt versus
8
versus b-sirt
8
balloon micro-catheter
8
trans-arterial loco-regional
8
versus b-deb-tace
8
deb-tace
6
[ci95%
6
versus
5
b-deb-tace
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!