A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The dosimetric impact of axillary nodes contouring variability in breast cancer radiotherapy: An AIRO multi-institutional study. | LitMetric

Aim: To quantify the dosimetric impact of contouring variability of axillary lymph nodes (L2, L3, L4) in breast cancer (BC) locoregional radiotherapy (RT).

Materials And Methods: 18 RT centres were asked to plan a locoregional treatment on their own planning target volume (single centre, SC-PTV) which was created by applying their institutional margins to the clinical target volume of the axillary nodes of three BC patients (P1, P2, P3) previously delineated (SC-CTV). The gold standard CTVs (GS-CTVs) of P1, P2 and P3 were developed by BC experts' consensus and validated with STAPLE algorithm. For each participating centre, the GS-PTV of each patient was created by applying the same margins as those used for the SC-CTV to SC-PTV expansion and replaced the SC-PTV in the treatment plan. Datasets were imported into MIM v6.1.7 [MIM Software Inc.], where dose-volume histograms (DVHs) were extracted and differences were analysed.

Results: 17/18 centres used intensity-modulated RT (IMRT). The CTV to PTV margins ranged from 0 to 10 mm (median 5 mm). No correlation was observed between GS-CTV coverage by 95% isodose and GS-PTV margins width. Doses delivered to 98% (D98) and 95% (D95) of GS-CTVs were significantly lower than those delivered to the SC-CTVs. No significant difference between SC-CTV and GS-CTV was observed in maximum dose (D2), always under 110%. Mean dose ≥99% of the SC-CTVs and GS-CTVs was satisfied in 84% and 50%, respectively. In less than one half of plans, GS-CTV V95% was above 90%. Breaking down the GS-CTV into the three nodal levels (L2, L3 and L4), L4 had the lowest probability to be covered by the 95% isodose.

Conclusions: Overall, GS-CTV resulted worse coverage, especially for L4. IMRT was largely used and CTV-to-PTV margins did not compensate for contouring issues. The results highlighted the need for delineation training and standardization.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2022.01.004DOI Listing

Publication Analysis

Top Keywords

dosimetric impact
8
axillary nodes
8
contouring variability
8
breast cancer
8
target volume
8
created applying
8
margins
5
gs-ctv
5
impact axillary
4
nodes contouring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!