This study investigated the ability of in vivo quantitative ultrasound (QUS) assessment to evaluate lymphedema severity compared with the gold standard method, the International Society of Lymphology (ISL) stage. Ultrasonic measurements were made around the middle thigh (n = 150). Radiofrequency data were acquired using a clinical scanner and 8-MHz linear probe. Envelope statistical analysis was performed using constant false alarm rate processing and homodyned K (HK) distribution. The attenuation coefficient was calculated using the spectral log-difference technique. The backscatter coefficient (BSC) was obtained by the reference phantom method with attenuation compensation according to the attenuation coefficients in the dermis and hypodermis, and then effective scatterer diameter (ESD) and effective acoustic concentration (EAC) were estimated with a Gaussian model. Receiver operating characteristic curves of QUS parameters were obtained using a linear regression model. A single QUS parameter with high area under the curve (AUC) differed between the dermis (ESD and EAC) and hypodermis (HK) parameters. The combinations with ESD and EAC in the dermis, HK parameters in the hypodermis and typical features (dermal thickness and echogenic regions in the hypodermis) improved classification performance between ISL stages 0 and ≥I (AUC = 0.90 with sensitivity of 75% and specificity of 91%) in comparison with ESD and EAC in the dermis (AUC = 0.82) and HK parameters in the hypodermis (AUC = 0.82). In vivo QUS assessment by BSC and envelope statistical analyses can be valuable for non-invasively classifying an extremely early stage of lymphedema, such as ISL stage I, and following its progression.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2021.12.003 | DOI Listing |
J Gastrointest Surg
December 2024
Department of Digestive Endoscopy, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu, China; Gusu College of Nanjing Medical University, Suzhou, Jiangsu, China. Electronic address:
Background: Endoscopic submucosal dissection (ESD) is a preferred method for early esophageal cancer, yet its application to esophageal adenocarcinoma (EAC), especially in the Eastern population with its relative rarity, lacks sufficient literature. This study evaluated ESD's long-term outcomes for EAC, focusing on noncurative resections and diagnostic accuracy.
Methods: Between 2012 and 2022, a retrospective study included 68 patients undergoing ESD for early EAC at Jiangsu Province Hospital.
Gastrointest Endosc
November 2024
Division of Gastroenterology, St. Michael's Hospital, University of Toronto, Toronto, Ontario, Canada.
Background And Aims: EMR and endoscopic submucosal dissection (ESD) are both accepted resection strategies for Barrett's esophagus-related neoplasia and esophageal adenocarcinoma (EAC). However, a lack of consensus exists regarding which technique offers superior outcomes. This study aims to systematically review the evidence comparing EMR versus ESD in treating Barrett's neoplasia and EAC.
View Article and Find Full Text PDFUltrasound Med Biol
June 2024
Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA; Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA; Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, USA. Electronic address:
Objective: The study described here was aimed at assessing the capability of quantitative ultrasound (QUS) based on the backscatter coefficient (BSC) for classifying disease states, such as breast cancer response to neoadjuvant chemotherapy and quantification of fatty liver disease. We evaluated the effectiveness of an in situ titanium (Ti) bead as a reference target in calibrating the system and mitigating attenuation and transmission loss effects on BSC estimation.
Methods: Traditional BSC estimation methods require external references for calibration, which do not account for ultrasound attenuation or transmission losses through tissues.
bioRxiv
February 2024
Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801.
Objectives: The study aims to assess the capability of Quantitative Ultrasound (QUS) based on the backscatter coefficient (BSC) for classifying disease states, such as breast cancer response to neoadjuvant chemotherapy and quantifying fatty liver disease. We evaluate the effectiveness of an titanium (Ti) bead as a reference target in calibrating the system and mitigating attenuation and transmission loss effects on BSC estimation.
Methods: Traditional BSC estimation methods require external references for calibration, which do not account for ultrasound attenuation or transmission losses through tissues.
Surg Endosc
March 2024
Division of Thoracic and Upper Gastrointestinal Surgery, Montreal General Hospital, McGill University Health Centre, 1650 Cedar Avenue, Montreal, QC, Canada.
Background: Management following endoscopic submucosal dissection (ESD) of pT1b esophageal adenocarcinoma (EAC) remains controversial. This study compared pathological and survival outcomes of patients after endoscopic resection (ER) of pT1b EAC followed by either en bloc esophagectomy or observation.
Methods: From 1/12 to 12/22, all patients with pT1b EAC treated with ER were identified from a prospectively maintained departmental database.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!