A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rotational stability and clinical outcomes of a new one piece toric intraocular lens with anchor-wing haptics. | LitMetric

Background: To evaluate the safety and efficacy of a new toric intraocular lens (IOL) with anchor-wing haptics.

Methods: The new toric IOL with anchor-wing haptics (NS60YT, NIDEK Co., Ltd.) was implanted in eligible patients with age-related cataracts with preoperative corneal astigmatism of 1.0 D or greater at a university hospital and two private hospitals in Japan. The following IOL cylinder powers were evaluated: 1.50 D (NS60YT3), 2.25 D (NS60YT4), 3.00 D (NS60YT5) and 4.50 D (NS60YT7). All patients were assessed out to 12 months postoperatively. The primary endpoint was visual acuity (VA) with spherical addition at 6 months postoperatively, and the primary analysis calculated the proportion of eyes with VA with spherical addition of 0.1 logMAR or better. The magnitude of rotation was compared to the intended axis of IOL implantation at each postoperative examination. Adverse events were evaluated for the safety analysis.

Results: This study enrolled 64 eyes of 53 patients. At 6 months postoperatively, for all IOL powers, VA with spherical addition of 0.1 logMAR or better was achieved in 90% [95% confidence interval (CI): 80-96] of eyes. The mean IOL rotation was 5.3 ± 4.3° at 12 months postoperatively. The mean magnitude of rotation ranged from 1.9° to 2.5° between each postoperative examination from 1 day to 12 months. There were no vision-threatening intraoperative or postoperative complications for the duration of the study.

Conclusions: The NS60YT IOL remained stable after implantation and was efficacious for treating 1.00 D or greater astigmatism in patients with senile cataracts.

Trial Registration: This study was registered at ClinicalTrials.gov ( NCT03242486 ) on August 8, 2017 - Retrospectively registered.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8761297PMC
http://dx.doi.org/10.1186/s12886-021-02240-7DOI Listing

Publication Analysis

Top Keywords

spherical addition
12
toric intraocular
8
intraocular lens
8
anchor-wing haptics
8
iol anchor-wing
8
12 months postoperatively
8
postoperatively primary
8
6 months postoperatively
8
addition logmar
8
logmar better
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!