A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Disposable Fluidic Devices of Bionanochannels for Enzymatic Monitoring and Energy Harvesting. | LitMetric

Nature produces a plethora of nanochannels to carry out highly complex biological tasks in a sophisticated manner. There have been several studies to understand the characteristics of these channels; however, efforts to apply them for technological advancements are still scarce. Here, we have demonstrated that the fluidic channels of biomaterials can be harvested as nanofluidic devices to produce energy from enzymatic chemical reactions. The bionanochannel-based nanofluidic devices exhibit various nanofluidic phenomena like surface-charged-governed ionic conductivity and development of the transmembrane potential. The mobility of ions in the hydrated bionanochannels are found to be higher than that of bulk water. The cation-selective nature of the biochannels was also exploited to harvest a continuous supply of power up to 74 mW m for 3 h from the enzymatic decomposition of urea. The transmembrane potential across the biochannels was also explored for label-free electrical monitoring of the enzymatic reaction inside the biological medium. Electrical monitoring on the kinetics of urease at different reaction temperatures suggested that inside biological medium the reaction goes through a pathway of lower activation energy (31.1 kJ) than that in the bulk environment (34.1 kJ). Enzyme urease was found to be more sustainable in bionanochannels than in glass vials.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsabm.9b00249DOI Listing

Publication Analysis

Top Keywords

nanofluidic devices
8
transmembrane potential
8
electrical monitoring
8
inside biological
8
biological medium
8
disposable fluidic
4
fluidic devices
4
devices bionanochannels
4
enzymatic
4
bionanochannels enzymatic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!