The objective of this study was to measure the effect of micromagnetic stimulation (MS) on hippocampal neurons, by using single microcoil (coil) prototype, magnetic pen (MagPen). MagPen will be used to stimulate the CA3 region magnetically and excitatory post synaptic potential (EPSP) response measurements will be made from the CA1 region. The threshold for micromagnetic neurostimulation as a function of stimulation frequency of the current driving thecoil will be demonstrated. Finally, the optimal stimulation frequency of the current driving thecoil to minimize power will be estimated.A biocompatible, watertight, non-corrosive prototype, MagPen was built, and customized such that it is easy to adjust the orientation of thecoil and its distance over the hippocampal tissue in anrecording setting. Finite element modeling of thecoil design was performed to estimate the spatial profiles of the magnetic flux density (in T) and the induced electric fields (in V m). The induced electric field profiles generated at different values of current applied to thecoil can elicit a neuronal response, which was validated by numerical modeling. The modeling settings for thecoil were replicated in experiments on rat hippocampal neurons.The preferred orientation of MagPen over the Schaffer Collateral fibers was demonstrated such that they elicit a neuron response. The recorded EPSPs from CA1 region due toMS at CA3 region were validated by applying tetrodotoxin (TTX). Application of TTX to the hippocampal slice blocked the EPSPs fromMS while after prolonged TTX washout, a partial recovery of the EPSP fromMS was observed. Finally, it was interpreted through numerical analysis that increasing frequency of the current driving thecoil, led to a decrease in the current amplitude threshold for micromagnetic neurostimulation.This work reports that micromagnetic neurostimulation can be used to evoke population EPSP responses in the CA1 region of the hippocampus. It demonstrates the strength-frequency curve forMS and its unique features related to orientation dependence of thecoils, spatial selectivity and stimulation threshold related to distance dependence. Finally, the challenges related toMS experiments were studied including ways to overcome them.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2552/ac4bafDOI Listing

Publication Analysis

Top Keywords

micromagnetic neurostimulation
12
ca1 region
12
frequency current
12
current driving
12
driving thecoil
12
strength-frequency curve
8
rat hippocampal
8
hippocampal neurons
8
numerical modeling
8
microcoil coil
8

Similar Publications

Micromagnetic stimulation (MS) dose-response of the rat sciatic nerve.

J Neural Eng

May 2023

Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States of America.

The objective of this study was to investigate the effects of micromagnetic stimuli strength and frequency from thenetic(MagPen) on the rat right sciatic nerve. The nerve's response was measured by recording muscle activity and movement of the right hind limb.The MagPen was custom-built to be stably held over the sciatic nerve.

View Article and Find Full Text PDF

The objective of this study was to measure the effect of micromagnetic stimulation (MS) on hippocampal neurons, by using single microcoil (coil) prototype, magnetic pen (MagPen). MagPen will be used to stimulate the CA3 region magnetically and excitatory post synaptic potential (EPSP) response measurements will be made from the CA1 region. The threshold for micromagnetic neurostimulation as a function of stimulation frequency of the current driving thecoil will be demonstrated.

View Article and Find Full Text PDF

A review on magnetic and spintronic neurostimulation: challenges and prospects.

Nanotechnology

February 2022

Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America.

In the treatment of neurodegenerative, sensory and cardiovascular diseases, electrical probes and arrays have shown quite a promising success rate. However, despite the outstanding clinical outcomes, their operation is significantly hindered by non-selective control of electric fields. A promising alternative is micromagnetic stimulation (MS) due to the high permeability of magnetic field through biological tissues.

View Article and Find Full Text PDF

A multichannel magnetic stimulation system using submillimeter-sized coils: system development and experimental application to rodent brain in vivo.

J Neural Eng

October 2019

Bioengineering and Bioinformatics, Graduate School of Informastion Science and Technology, Hokkaido University, Kita-14, Nishi-9, Kita-ku, Sapporo 060-0814, Japan.

Objective: Single coil-based systems for magnetic stimulation are widely used for neurostimulation in neuroscience research and clinical treatment of neurological diseases. However, parallelization of magnetic stimulation with multiple coils may generate far greater potential than a single coil, and could thus expand the scope of brain area stimulation. Therefore, we examined whether a multiple coil-based system could improve the effectiveness and focality of conventional single coil-based magnetic stimulation.

View Article and Find Full Text PDF

Electrical stimulation of the central and peripheral nervous systems - such as deep brain stimulation, spinal cord stimulation, and epidural cortical stimulation are common therapeutic options increasingly used to treat a large variety of neurological and psychiatric conditions. Despite their remarkable success, there are limitations which if overcome, could enhance outcomes and potentially reduce common side-effects. Micromagnetic stimulation (μMS) was introduced to address some of these limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!