A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The influence of delivery power losses and full operating parametry on the effectiveness of diode visible-near infra-red (445-1064 nm) laser therapy in dentistry-a multi-centre investigation. | LitMetric

The development of protocols for laser-assisted therapy demands strict compliance with comprehensive operating parametry. The purpose of this investigation was to examine the accuracy of correlation between laser control panel and fibre emission power values in a selection of diode dental lasers. Through retrospective analysis using successive systematic review and meta-analysis, it is clear that there is inconsistency in the details, and possible inaccuracies in laser power applied and associated computed data. Through a multi-centre investigation, 38 semi-conductor ("diode") dental laser units were chosen, with emission wavelengths ranging from 445 to 1064 nm. Each unit had been recently serviced according to manufacturer's recommendations, and delivery fibre assembly checked for patency and correct alignment with the parent laser unit. Subject to the output capacity of each laser, four average power values were chosen using the laser control panel-100 mW, 500 mW, 1.0 W, and 2.0 W. Using a calibrated power meter, the post-fibre emission power value was measured, and a percentage power loss calculated. For each emission, a series of six measurements were made and analysed to investigate sources of power losses along the delivery fibre, and to evaluate the precision of power loss determinations. Statistical analysis of a dataset comprising % deviations from power setting levels was performed using a factorial ANOVA model, and this demonstrated very highly significant differences between devices tested and emission power levels applied (p < 10-142 and < 10-52 respectively). The devices × emission power interaction effect was also markedly significant (p < 10-66), and this confirmed that differences observed in these deviations for each prior power setting parameter were dependent on the device employed for delivery. Power losses were found to be negatively related to power settings applied. Significant differences have emerged to recommend the need to standardize a minimum set of parameters that should form the basis of comparative research into laser-tissue interactions, both in vitro and in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10103-021-03491-yDOI Listing

Publication Analysis

Top Keywords

emission power
12
power
11
power losses
8
operating parametry
8
multi-centre investigation
8
laser control
8
power values
8
delivery fibre
8
power loss
8
laser
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!