Aerosol particles are one of the main routes of transmission of COVID-19. Mobile air purifiers are used to reduce the risk of infection indoors. We focus on an air purifier that generates a defined volumetric air flow through a highly efficient filter material. We investigate the transport of aerosol particles from an infected dummy equipped with an aerosol generator to receiving thermal dummies. For analysis, we use up to 12 particle sensors to monitor the particle concentration with high spatial resolution. Based on the measurement data, a computational fluid dynamics (CFD) model is set up and validated. The experimental and numerical methods are used to investigate how the risk of infection suggested by the particle exposure in an exemplary lecture hall can be reduced by a clever choice of orientation of the air purifier. It turns out that obstructing the outlet stream of the air purifier may be particularly advantageous. The particle concentration at the head height deviates by 13% for variations of the location and orientation. At an air change per hour of 5, the cumulated PM1 mass at the head level was reduced by 75%, independently of the location of the infected dummy, compared to the "natural decay" case, showing that filtration is an effective means of reducing aerosol particle concentrations. Finally, CFD simulation was used to monitor the particle fates. The steady simulation results fit quite well with the experimental findings and provide additional information about the particle path and for assessing the comfort level due to air flow.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8730331 | PMC |
http://dx.doi.org/10.1063/5.0064805 | DOI Listing |
J Infect Public Health
January 2025
Dalla Lana School of Public Health, University of Toronto, 155 College St., Toronto, Ontario M5T 3M7, Canada; Department of Civil & Mineral Engineering, 35 St. George St, Toronto, Ontario M5S 1A4, Canada.
Throughout the COVID-19 pandemic, Canadian public health advisors and politicians have shared mixed messages about the utility of portable air filters (PAFs) for mitigating the transmission of airborne infectious diseases. Some public health advisors and decision-makers have also suggested that PAFs are cumbersome or require expert advice. We take this opportunity to review evidence and address myths about PAFs.
View Article and Find Full Text PDFHealth Phys
January 2025
National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, 100088, China.
Inhalation of 131I is the main route for internal doses to nuclear medicine workers. This study aimed to establish a simple analysis method for determining 131I activity in carbon cartridges, explore the activity concentration of 131I in nuclear medicine departments, and evaluate the internal dose of workers. A total of 21 nuclear medicine departments in the hospital conducted air sampling using a high-volume air sampler equipped with carbon cartridges and glass fiber filters to collect gaseous 131I and aerosol 131I, respectively.
View Article and Find Full Text PDFEClinicalMedicine
January 2025
WEISS Centre, University College London, UK.
Background: The COVID-19 pandemic highlighted the need for improved infectious aerosol concentrations through interventions that reduce the transmission of airborne infections. The aims of this review were to map the existing literature on interventions used to improve infectious aerosol concentrations in hospitals and understand challenges in their implementation.
Methods: We reviewed peer-reviewed articles identified on three databases, MEDLINE, Web of Science, and the Cochrane Library from inception to July 2024.
J Expo Sci Environ Epidemiol
January 2025
Department of Environmental and Occupational Health, Joe C. Wen School of Population & Public Health, University of California, Irvine, CA, USA.
Background: Children living in communities with lower socioeconomic status and higher minority populations are often disproportionately exposed to particulate matter (PM) compared to children living in other communities.
Objective: We assessed whether adding HEPA filter air cleaners to classrooms with existing HVAC systems reduces indoor air pollution exposure.
Methods: From July 2022 to June 2023, using a block randomized crossover trial of 17 Los Angeles Unified School District elementary schools, classroom PM concentrations were monitored and compared for 99 classrooms with HEPA filter air cleaners and 87 classrooms with non-HEPA filter air cleaners.
Environ Int
January 2025
Blue Growth Research Lab, Ghent University, Wetenschapspark 1, Bluebridge, 8400 Oostende, Belgium. Electronic address:
Sea spray aerosol (SSA) is a complex mixture of natural substances that can be inhaled by coastal residents. Previous studies have suggested that SSA may have positive effects on human health, but the molecular mechanisms and the factors influencing these effects are poorly understood. In this study, we exposed human bronchial epithelial cells (BEAS-2B) to natural SSA samples, collected monthly using quartz microfiber filters mounted on tripods within 15 m of the waterline, with air drawn through pumps, throughout a one-year period at the Ostend coast, Belgium, and measured cellular gene expression changes using RNA sequencing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!