To treat large intracranial aneurysms, pipeline embolization device (PED) stent with unsupervised learning algorithms was utilized. Unsupervised learning model algorithm was used to screen aneurysm health big data, find aneurysm blood flow and PED stent positioning characteristic parameters, and guide PED stent treatment of intracranial aneurysms. The research objects were 100 patients with intracranial large aneurysm admitted to X Hospital of X Province from June 2020 to June 2021, who were enrolled into two groups. One group used the prototype transfer generative adversarial network (PTGAN) model to measure mean blood flow and mean vascular pressure and guide the placement of PED stents (PTGAN group). The other group did not use the model to place PED (control group). The PTGAN model can learn feature information from horizontal and vertical directions, with smooth edges and prominent features, which can effectively extract the main morphological and texture features of aneurysms. Compared with the convolutional neural network (CNN) model, the accuracy of the PTGAN model increased by 8.449% (87.452%-79.003%), and the precision increased by 8.347% (91.23%-82.883%). The recall rate increased by 7.011% (87.231%-80.22%), and the 1 score increased by 8.09% (89.73%-81.64%). After the adoption of the PTGAN model, the average blood flow inside the aneurysm body was 0.22 (m/s). After the adoption of the CNN model, the average blood flow inside the aneurysm body was 0.21 (m/s), and the difference was 0.01 (m/s), which was considerable ( < 0.05). Through this research, it was found that the PTGAN model was better than the CNN model in terms of accuracy, precision, recall, and 1 score values. The PTGAN model was better than the CNN model in detecting the average blood flow rate and average blood pressure after treatment, and the blood flowed smoothly. Postoperative complications and postoperative relief were also better than those of the control group. In summary, based on the unsupervised learning algorithm, the PED stent had a good adoption effect in the treatment of intracranial aneurysms and was suitable for subsequent treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8752217PMC
http://dx.doi.org/10.1155/2022/8509195DOI Listing

Publication Analysis

Top Keywords

ptgan model
24
blood flow
20
unsupervised learning
16
ped stent
16
cnn model
16
average blood
16
intracranial aneurysms
12
model
12
pipeline embolization
8
embolization device
8

Similar Publications

Multimodal image synthesis has emerged as a viable solution to the modality missing challenge. Most existing approaches employ softmax-based classifiers to provide modal constraints for the generated models. These methods, however, focus on learning to distinguish inter-domain differences while failing to build intra-domain compactness, resulting in inferior synthetic results.

View Article and Find Full Text PDF

To treat large intracranial aneurysms, pipeline embolization device (PED) stent with unsupervised learning algorithms was utilized. Unsupervised learning model algorithm was used to screen aneurysm health big data, find aneurysm blood flow and PED stent positioning characteristic parameters, and guide PED stent treatment of intracranial aneurysms. The research objects were 100 patients with intracranial large aneurysm admitted to X Hospital of X Province from June 2020 to June 2021, who were enrolled into two groups.

View Article and Find Full Text PDF

In this work, we report an ultra-high sensitive (S = 1.4 × 10%), prompt response and recovering Pt/Pt+SiO cermet layer/GaN-based hydrogen (H) sensor. A sensor fabricated with a 15 nm cermet layer, comprising Pt and SiO, deposited between 15 nm Pt and GaN layers, exhibits significantly enhanced sensitivity in the detection of 4 %H by ≈ 300×, as compared to the reference Pt/GaN sensor at ambient temperature (300 K).

View Article and Find Full Text PDF

Temperature-dependent electrical characterization of Pt/n-GaN Schottky barrier diodes prepared by ultra high vacuum evaporation has been done. Analysis has been made to determine the origin of the anomalous temperature dependence of the Schottky barrier height, the ideality factor, and the Richardson constant calculated from the I-V-T characteristics. Variable-temperature Hall effect measurements have been carried out to understand charge transport at low temperature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!