Central venous catheter (CVC) insertion is a commonly performed procedure that is used for continuous invasive hemodynamic monitoring, fluid resuscitation, drug therapy, and hemodialysis. CVC placement can be associated with serious complications that are mostly preventable. One of these complications is the loss of the guidewire within the intravascular space, which carries a high morbidity and mortality. Here, we describe a 44-year old patient who presented with acute kidney injury and metabolic derangements that necessitated bedside right femoral dialysis catheter to initiate emergent renal replacement therapy. A day after the catheter insertion, the guidewire was noted on a routine chest X-ray extending into the base of the skull. The clinical course was complicated with cerebral infarction. Subsequently, the retained guidewire was removed a few days after the CVC insertion. In summary, the retained guidewire within the circulation is associated with potentially life-threatening and hazardous outcomes. Continuing education, vigilant supervision, and implementing certain protocols are likely to prevent such undesirable events.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8715130PMC
http://dx.doi.org/10.1016/j.radcr.2021.11.030DOI Listing

Publication Analysis

Top Keywords

retained guidewire
12
bedside femoral
8
venous catheter
8
catheter insertion
8
cvc insertion
8
guidewire
5
delayed diagnosis
4
diagnosis retained
4
guidewire bedside
4
femoral venous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!